4) Installation example
During installation, strictly observe the related operating conditions in “3.4 Special installation”.
7
Wire hanging
Attach wires to the bolts, as indicated in the figure.
To attach the wires to the ceiling, secure two wires at
two independent points for safety.
• To keep the plasma display main body from vibrating,
fix the main body by attaching wire to the bottom bolt.
• Use wires strong enough to withstand the total weight
(30.8 kg <31.6 kg> for the plasma display itself plus
3.3 kg for the PDP bracket).
< > shows the PDP-V401E.
Use the Special eye bolt only at the specified locations.
Improper use of Special eye bolts within the plasma display main body may
damage the display's blind nut.
Mounting standard metal fixtures (PDK-4005)
Caution
Special eye
bolt
Wire
Wire
PDP bracket
Do not attempt to correct tilt by applying downward load with the wires. Doing so may apply
excessive load upon and damage the wire connections and metal mounting fixture.