Special installations (Wall embedding)
A
\
\
X
Y
A
B
A
C
Exhaust
B
(3) When the back of the wall is in a closed space:
Operating this display in confined spaces is not recommended.
• If the display is to be used in confined spaces, observe the following conditions shown in the drawing above:
A
≥
150 mm
B
≥
250 mm
C
≥
30 mm
•
Keep the temperature in the closed space “Y” and the open space “X” at 40 °C or less. In particular,
the space “Y” should be ventilated sufficiently by the air conditioner or fan so that hot air is not
trapped in the space. Thus, everywhere in “Y” must be kept at 40°C or less.
If hot air remains in the
closed space, the temperature may rise, causing a malfunction or fire. As a precaution in case of accidents,
the inner wall should have sufficient heat resistance or fire resistance. Direct air from the air conditioner in the
direction of the arrow (from where no fan is installed to where a fan is provided).
70 mm or less (on both left and right)
MAX. 20 mm (on both left and right)
Flow of air from the
air conditioner
Exhaust fan (air flow rate:
2 m
3
/min or more)
Intake port
A
C
100 mm
100 mm
Summary of Contents for PDA-4001
Page 5: ...5 Ver 2 1 Features ...
Page 19: ...19 Ver 2 1 Installation procedure ...
Page 53: ...53 Ver 2 1 Special installation Horizontal connections ...
Page 63: ...63 Ver 2 1 Mounting standard metal fixtures PDK 4001 ...
Page 69: ...69 Ver 2 1 Mounting standard metal fixtures PDK 4002 ...
Page 75: ...75 Ver 2 1 Mounting standard metal fixtures PDK 4004 ...
Page 89: ...89 Ver 2 1 Mounting standard metal fixtures PDK 4006 ...
Page 101: ...101 Ver 2 1 Mounting standard metal fixtures Precautions for installing the optional speaker ...