52
<Ver. 2.1>
3
PDK-4005 wall-mounted Horizontal connections (maximum of four units)
If the device must be used at temperatures at or above the given levels and four or more displays are to be used,
provide forced-air cooling with fans or air conditioning so that temperatures at the intake and exhaust sides of the
A and B units remain within the recommended range.
The following table provides recommended operating temperatures for side-by-side installations of the PDK-4005.
A-unit
B-unit
C-unit
D-unit
W
W
W
Special installation (Horizontal connections)
Clearance W between the sets
400 mm
≤
W
20
≤
W < 400
W < 20
Ambient operating temperatures
0 to 35 °C
0 to 30 °C (Still)
0 to 35 °C (Animation)
Cannot be used.
Air temperature
+ 5 °C, maximum
of 40 °C
Air temperature
+ 15 °C
10 mm
10 mm