3.4.3 Wall embedding
This display is designed to accommodate embedding in a wall. Note that the allowable range of outside-air temperature
depends on the installation conditions. Please observe the following requirements:
1
If the unit must be embedded in the wall, you must not block the side slots of the unit.
Avoid blocking the ventilating holes in the rear as much as possible.
2
Use a metal mounting fixture that does not block the side slits or the back ventilation holes, and attach at a
minimum of four points. To avoid breaking the PDP panel, limit any twisting or bending stress applied to the
display to 1 mm or less.
3
Do not use cable clamps for this installation method. Cable clamps can interfere with proper ventilation and
result in device failure.
4
Installation conditions and ambient operating temperatures:
(1) If the back of the display will be unobstructed:
Never block the side slots. Avoid
blocking the ventilating holes of the
unit as much as possible.
Side slits
Special installations (Wall embedding)
A
≥
100 mm, B
≤
150 mm
A
≥
100 mm, B
≥
150 mm
A
≤
100 mm, B
≤
80 mm
A
≤
100 mm, B
≥
80 mm
X, Y space upper temperature limits
40 °C
40 °C (Animation), 35 °C (Still)
40 °C
35 °C
C
B
A
B
A
B
C
B
X
Y
Intake
MAX 20 mm
Exhaust
Take C to be 30 mm or more.
A
A
100 mm
100 mm
Caution
Summary of Contents for PDA-4001
Page 5: ...5 Ver 2 1 Features ...
Page 19: ...19 Ver 2 1 Installation procedure ...
Page 53: ...53 Ver 2 1 Special installation Horizontal connections ...
Page 63: ...63 Ver 2 1 Mounting standard metal fixtures PDK 4001 ...
Page 69: ...69 Ver 2 1 Mounting standard metal fixtures PDK 4002 ...
Page 75: ...75 Ver 2 1 Mounting standard metal fixtures PDK 4004 ...
Page 89: ...89 Ver 2 1 Mounting standard metal fixtures PDK 4006 ...
Page 101: ...101 Ver 2 1 Mounting standard metal fixtures Precautions for installing the optional speaker ...