Chapter 5: System Maintenance
56
Deko1000 & Deko550 Technical Reference And Service Guide
2. Release locking latch and pull the Power Supply from the Deko1000 or Deko550
Workstation.
Slide the locking latch (see Figure 5-14) switch up to release the lock. Then grab the Power
Supply unit’s handle and pull the Power Supply straight out from the workstation. Refer to
Figure 5-15. Set the damaged unit aside.
Figure 5-15: Hard drive out from drive bay
3. Remove the new Power Supply from its antistatic bag.
Handle the new Power Supply with care.
4. Push the new Power Supply all the way into the drive bay.
Align the Power Supply so that it will properly slide into its bay, slide the locking latch up,
and then push the Power Supply so that it completely slides into the bay. This will connect
the Power Supply to its connectors at the back of the bay. Make sure the locking latch slides
down to lock the Power Supply into place.
5. Plug in power cord and switch Power Supply to On.
When the Power Supply is switched to the On (i.e., “I”) position, its LED should light.
Important:
If the LED on the unit does not light, check both ends of the unit’s power cord and also
make sure the workstation is turned on as well. If the LED still does not light and you are sure the
unit is receiving power and the workstation is on, contact Pinnacle Customer Support. Refer to
Appendix A for contact information.
6. Return the damaged Power Supply to Pinnacle Systems.
Place the damaged Power Supply into the antistatic bag that the replacement unit was pulled
from, and send the damaged unit to Pinnacle Systems per the instructions given by Pinnacle
Support.