Chapter 4: Troubleshooting
36
Deko1000 & Deko550 Technical Reference And Service Guide
If manual tests pass:
When a manual test is done, a Pass/Fail message will be displayed in a column to the right of the
test name. Refer to Figure 4-12. If the manual test(s) you needed to run passes, and there is more
than one TARGA card in the workstation, repeat Steps 1-4 above for each TARGA card.
If a manual tests fails:
When a manual test is done, a Pass/Fail message will be displayed in a column to the right of the
test name. Details about a test that fails can be viewed by clicking on the test name with a single
left mouse click which will highlight the test name and test result. Once highlighted, right double
click on the highlighted name for a dialog detailing the failure. If it was one of the SDI Channel
tests that failed, check that the loop through cables are connected properly to the TARGA card
being tested. If a genlock tests failed, check the signal input on the Reference. (Refer to the
“Setup Before Testing” section above for manual testing setup procedures.)
Perform the following steps if a test fails
1. Repeat the manual test.
Make sure that the TARGA card is properly seated, and loop through cables are secure and
properly connected before repeating the manual test.
Important:
Power down the workstation before removing the cover to make sure that the TARGA
card is properly seated in its PCI slot.
2. If the test fails again, save the results.
Results can be saved by right clicking on the blue title bar or red icon (upper left-hand
corner) of the Inflexion I/O Diagnostic window and selecting “Save Results.” Refer to
Figure 4-13.
Figure 4-13: Selecting “Save Results” for a manual test failure
When saved results is selected, the window shown in Figure 4-14 will be displayed.