6.5.2 - IN-LINE EQUIPMENT INSTALLATION PROCEDURE
WITH SPACER
The equipment can be installed by inserting a spacer. This configuration is used to service the reinforced gasket without
removing the regulator from the line.
Fig. 6.19.
ASX 176 installation with spacer
Step Action
1
Place the equipment in the section of the line designated for it.
2
Place the gaskets between the line flange and the upstream regulator flange.
3
Insert the bolts into the appropriate holes of the upstream connecting flanges.
4
Place a gasket between the spacer and the regulator.
5
Place a gasket between the spacer and the downstream pipe flange.
6
Insert the bolts into the appropriate holes of the downstream connecting flanges.
7
Screw the bolts following the technical rules for tightening flanges.
Tab. 6.41.
NOTICE!
For installation after maintenance, replace the gaskets and clean the flange bearing surface.