177
ASX 176
Use, maintenance and warning instructions
HIGH PRESSURE REGULATOR
|
MAINTENANCE AND FUNCTIONAL CHECKS
|
REV. 00
EN
To disconnect the pilot, proceed as in Table 9.95:
Step Action
1
Disconnect the sensing lines between the 200/A pilot and the regulator by adjusting the fittings (1, 2, 3).
2
Unscrew and remove the fixing screw to remove the pilot from the regulator.
3
Remove the pipe (20) by adjusting the fittings (4, 5).
4
Unscrew and remove the screw (6) to separate the R14/A pre-regulator from the pilot.
5
Undo and remove the screw (7) from pilot 200/A.
Tab. 9.96.