195
ASX 176
Use, maintenance and warning instructions
HIGH PRESSURE REGULATOR
|
MAINTENANCE AND FUNCTIONAL CHECKS
|
REV. 00
EN
Step Action
24
Remove the O-ring (43) from the plug guide (9) and replace it, taking care to lubricate it with synthetic grease.
NOTICE!
Before inserting the replacement O-ring, clean the retaining slots with a cleaning solution.
25
Fit the plug guide (9) together with the reinforced gasket (7).
26
Place the gasket support (1) in the body (10).
27
Take out the diaphragm/plug unit (8, 11, 12, 25, 29, 31).
NOTICE!
Before inserting the diaphragm/plug unit, lubricate the plug (8) surface with silicone grease.
28
Fit the sleeve (15) and the bracket (53).
29
Insert and fix the screws (33).
NOTICE!
Tighten the screws according to the cross diagram in paragraph 9.4.2.2.
30
Position the upper spring support (14) together with the spring (22).
31
Fit the lower spring support (16) together with the ring (55).
32
Fit and secure the cap (17).
33
Remove and replace the O-ring (46) in the nut (27).
NOTICE!
Before inserting the replacement O-ring, clean the retaining slots with a cleaning solution.
34
Fit the adjusting screw (28) together with the nut (27).
Tab. 9.101.
WARNING!
Ensure that all parts have been fitted correctly.