65
ASX 176
Use, maintenance and warning instructions
HIGH PRESSURE REGULATOR
|
TRANSPORT AND HANDLING
|
REV. 00
EN
5.5 - STORAGE AND ENVIRONMENTAL CONDITIONS
If the equipment needs to be stored for an extended period, the minimum environmental conditions for the intended stor-
age are provided. Only by complying with these requirements can the declared performance be guaranteed:
Conditions
Data
Maximum storage period
Maximum 3 years.
NOTICE!
For installations in later periods, see paragraph
“pre-installation warnings after prolonged storage.
Temperature
Not above 40°C
Humidity
Not above 70%
Radiation
Away from radiation sources according to UNI ISO 2230:2009
Tab. 5.37.
5.5.1 - PRE-INSTALLATION WARNINGS AFTER PROLONGED STORAGE
For installations that have been stored for longer than 3 years, the condition of all rubber parts must be checked and, if
found to be damaged, they must be replaced in order to ensure the correct functioning of the equipment.
To replace the rubber parts of the equipment, please refer to chapter 9 “Maintenance and functional checks”.
NOTICE!
PIETRO FIORENTINI S.P.A. recommends checking the condition of rubber parts in case of downtime or
storage longer than 3 years.