239
ASX 176
Use, maintenance and warning instructions
HIGH PRESSURE REGULATOR
|
TROUBLESHOOTING
|
REV. 00
EN
Failure
Device
Possible causes
Service
Downstream pressure
decreases on
delivery
REGULATOR
Breakage of the diaphragm (50) Replace
O-ring (48) not sealing
Clean and replace if needed
I/DWR friction (52)
Lubricate and replace if neces-
sary
Plug (9) locked
Clean
No upstream pressure
Check clogging of line filter
cartridges
Ice formation
Increasing the gas tempera-
ture at the regulator inlet
O-ring (48) not sealing
Clean and replace if needed
R14 PRE-REGULATOR
Diaphragm (10) damaged
Replace
200/A SERIES PILOT
Plug (17) damaged
Replace
Diaphragm holder assembly
(16) and plug (17) locked in
shut-off position
Check and clean if necessary
Downstream sensing line ob-
structed
Clean
Tab. 10.113.
10.4.2 - TROUBLESHOOTING OF SILENCER LDB/176
Failure
Device
Possible causes
Service
Downstream pressure
decreases
LDB/176
Grid (70) dirty
Clean
Tab. 10.114.