72
ASX 176
EN
Use, maintenance and warning instructions
HIGH PRESSURE REGULATOR
|
INSTALLATION
|
REV. 00
6.5 - EQUIPMENT INSTALLATION PROCEDURES
6.5.1 - IN-LINE EQUIPMENT INSTALLATION PROCEDURE
Fig. 6.18.
ASX 176 installation without spacer
Step Action
1
Place the equipment in the section of the line designated for it.
2
Place the gaskets between the line flanges and the regulator flanges.
3
Insert the bolts into the appropriate holes of the connecting flanges.
4
Screw the bolts following the technical rules for tightening flanges.
Tab. 6.40.
NOTICE!
For installation after maintenance, replace the gaskets and clean the flange bearing surface.
Summary of Contents for ASX 176