31
13.
System schemes
It is possible to choose between different hydraulic
schemata, which reflect a certain structure of the system
with a different configuration of the function units (system
modules). The respective function volume is set by the
appropriate options (e.g. reflux lift, unmixed heating circuit,
...).
Solar systems are not shown, but it can be selected, which heating target is associated with it (buffer
tank, hot water tank, generic heating target such as swimming pool).
External heat sources are optionally available and are hydraulically similar to the connected heat
generator. They have an autonomous (external) controlled circulation pump.
The selection of a schema takes place by confirming the line System scheme and entering the number
of the desired schema.
shortcuts Definition of terms
FU
Function unit
N/A
Not available
T1
Flow temperature of heat generator
T2
Reflux temperature of heat generator
T3
Exterior temperature
T4
Heat buffer temperature top
T5
Heat buffer temperature bottom
T7
Hot water temperature tank x
T8
Cold buffer temperature top
T9
Cold buffer temperature bottom
T10
Collective flow tank for cascades
Tx
Temperature flow of heating/cooling
circuit x
shortcuts Definition of terms
P1
Pump heat generator
P7
Loading pump of hot water tank x
Px
Pump of heating/cooling circuit x
M1
Mixer reflux lift (optional)
Mx
Mixer hot water tank x
V1
Switch valve buffer / hot water tank
V2
Switch valve heating / cooling
Vx
Switch valve heating / cooling of
heating/cooling circuit x
V4
Switch valve Buffer / heating circuit