5.
Firmware Upgrading & Diagnostic Software
Nucleus Name
DS_HDMI_FLI2310_ExtendedWrite
Nucleus Number
1517
Description
Write to any register of the FLI2310
Technical
-
Execution Time
Less than 1 second.
User Input
<Register> <RegLen:1=8bits;2=16bits> <Data>
Error Number
Description
151700
The IIC write action succeeded
151701
Failed to retrieve the hardware diversity string
151702
Failed to initialise the IIC communication
151703
The hardware was not detected although indicated by Diversity
151704
Decoding register unsigned value failed
151705
Decoding register length unsigned value failed
151706
Decoding register data unsigned value failed
151707
Error writing to register
Example
DS:> 1517 0x303 1 0x9a
151700:
Test OK @
Nucleus Name
DS_HDMI_FLI2310_ExtendedRead
Nucleus Number
1518
Description
Read from any register of the FLI2310
Technical
-
Execution Time
Less than 1 second.
User Input
<Register> <RegLen:1=8bits;2=16bits>
Error Number
Description
151800
The IIC read action succeeded
151801
Failed to retrieve the hardware diversity string
151802
Failed to initialise the IIC communication
151803
The hardware was not detected although indicated by Diversity
151804
Decoding register unsigned value failed
151805
Decoding register length unsigned value failed
151806
Error reading from the register
Example
DS:> 1518 0x303 1
151800: Data read: 0x009A
Test OK @
Nucleus Name
DS_HDMI_FLI2310_1080I
Nucleus Number
1519
Description
Set the Faroudja FLI2310 to generate a 1080I image from the video on its
inputs.
Technical
-
Execution Time
Less than 1 second.
User Input
None
Error Number
Description
151900
Generating the up-scaled image succeeded
151901
Failed to retrieve the hardware diversity string
151902
Failed to initialise the IIC communication
151903
The hardware was not detected although indicated by Diversity
151904
Generating the up-scaled image failed
Example
DS:> 1519
151900:
Test OK @