EN 19
3139 785 31681
5.
Firmware Upgrading & Diagnostic Software
User Input
The user has to decide which test image, video standard and video output must
be used: < Test image id > < Video standard > < Video output >
Test image id:
0
VERTICAL_COLOURBAR (default)
1
HORIZONTAL_COLOURBAR
2
WHITE
3
YELLOW
4
CYAN
5
GREEN
6
MAGENTA
7
RED
8
BLUE
9
BLACK
10
GRAY
11
TEST_IMAGE_FOR_PROGRESSIVE_SCAN
Video standard:
PAL
Standard PAL 50 Hz (default)
NTSC
Standard NTSC 60 Hz
Video output:
ALL
CVBS and YC and RGB DACs are enabled (default)
CVBS
CVBS DAC is enabled
YC
Y and C DAC is enabled
RGB
CVBS, R, G, and B DACs are enabled
YUV
Y, U, and V DACs are enabled
PSCAN
Progressive scan is enabled.
Error
Number
Description
10100
Generating the test image succeeded.
10101
Invalid input was provided.
10102
The Codec SYNC-module cannot be initialised.
10103
The Codec MIXER-module cannot be initialised.
10104
The Codec VPP-module cannot be initialised.
10105
The Codec DENC-module cannot be initialised.
10106
The digital board hardware information is corrupt
Example
DS:> 101
010100:
Test OK @
DS:> 101 0 pal cvbs
010100:
Test OK @
DS:> 101 4 ntsc yc
010100:
Test OK @
Nucleus Name
DS_CHR_TestImageOff
Nucleus Number
102
Description
Switches the test-image off.
Technical
-
Stop the DENC module.
Execution Time
Less than 1 second.
User Input
None
Error
Number
Description
10200
Stopping the test image generation succeeded
10201
The Codec DENC-module failed.
Example
DS:> 102
010200: