Magnum C3C Spreader Sprayer
Operator Manual
Refer to the cover page for restrictions regarding
reproduction or disclosure of this material.
Page 59
September/08
MAINTENANCE (continued)
b.
Check the machine hour meter. When it flashes LUBE perform the 25-hour
maintenance listed below. The Hour meter will stop flashing automatically whether
maintenance has been done or not.
c.
Perform the maintenance and inspections in the Daily Maintenance Checklist
provided in the Maintenance section. Record all check results in the Daily
Maintenance Checklist.
d.
Clean the air filter.
e.
Clean debris from engine and muffler.
f.
Grease the rear wheel bearings using Mobillux EP 2 grease, or equivalent. Each
wheel has a zerk fitting. If a fitting is missing, replace the fitting.
g.
Grease the articulating rod ends between the spreader and sulky using Mobillux EP
2 grease, or equivalent. Each rod end has a zerk fitting. If a fitting is missing,
replace the fitting.
h.
Grease each pillow block on the jackshaft located under the hood, using Mobillux EP
2 grease, or equivalent. Each pillow block has a zerk fitting. If a fitting is missing,
replace the fitting.
i.
Grease each zerk fitting (2) on front, underside of transmission/axle using Mobillux
EP2 grease, or equivalent.
j.
Grease each zerk fitting (2) on front wheel hubs using Mobillux EP2 grease, or
equivalent.
k.
If the spreader or sprayer requires calibration, refer to the procedures in section 4,
CALIBRATION AND ADJUSTMENT.
l.
Perform Safety Systems Check (refer to Section 3).
6. Scheduled maintenance to be performed MONTHLY or every 100 hours of operation. When
you perform this maintenance, date the maintenance log, initial the log, and check off each
procedure. Pay particular attention to the following items:
a.
Make copies of the Scheduled Maintenance Log to be used for this machine.
Record completion of each maintenance item. Keep the copy with your Operators
Manual.
b.
Check the machine hour meter. When it flashes LUBE perform the 25-hour
maintenance listed below. The Hour meter will stop flashing automatically whether
maintenance has been done or not.