5.3 Correction factors according to defrosting operation
The heating capacity in previous part, excludes the condition of defrosting operation period. In
consideration of defrosting operation, the heating capacity is corrected by the equation below.
Corrected heating capacity = Defrost Correction factor x unit capacity
Correction Factor
NOTE:
The correction factor is not valid for special conditions such as snowfall or operation in a transitional period.
Heating
capacity
Reduction in capacity due to
white frost
1 cycle
Hour
Defrost max. 12mins
OUTDOOR TEMPERATURE [
℉
(℃
)
DB]
5(-15)
14(-10)
23(-5)
32(0)
44.6(7)
50(10)
59(15)
Correction factor
(humidity rate 85% RH)
0.95
0.95
0.92
0.84
1.0
1.0
1.0
20