1
4
.TROUBLESHOOTING
Fault
code
Fault description
Possible reasons for abnormality
How to deal with
16
Low DC voltage 200V
1. Voltage input is too low;
2. Drive board fault.
1. Check the power supply.
2. Change the driver board.
18
Driver board read EE
data error
1. EEPROM has no data or data error;
2. EEPROM circuit fault.
1. Change EEPROM component;
2. Change the driver board.
19
PFC chip receive data
fault
Abnormal communication loop.
Change the drive board.
20
PFC soft start
abnormal
Abnormal PFC drive loop.
Change the drive board.
21
The compressor drive
chip could not receive
data from PFC chip.
Communication loop fault.
Change the drive board.
62
Summary of Contents for 3PAMSHHQC18-MZO2
Page 12: ...3 OUTLINES AND DIMENSIONS 3 Outlines and dimensions 18K Unit in mm 8...
Page 15: ...42K Unit in mm 3 OUTLINES AND DIMENSIONS 11...
Page 26: ...7 REFRIGERANT CYCLE 7 Refrigerant cycle 18K 24K 22...
Page 29: ...8 WIRING DIAGRAM 24K Electric wiring diagram 1993419 F 25...
Page 30: ...8 WIRING DIAGRAM 36K Electric wiring diagram 2000947 H 26...
Page 31: ...8 WIRING DIAGRAM 42K Electric wiring diagram 2087381 B 27...