1
4
.TROUBLESHOOTING
Fault
code
Fault
d
escription
Possible
r
eason
s for
a
bnormality
How to
d
eal
w
ith
R
emarks
46 IPM and control board
communication fault
1.The cable between the control
board and the driver board is
connected loosely;
2.The cable between the control
board and the driver board
fails;
3.The driver board fails
;
4.The control board fails.
1.Reconnect the cable between
the control board and the
driver board;
2.Replace the communication
cable between the control
board and the driver board;
3.Replace the driver board;
4.Replace the control board.
47 Too high discharge
temperature fault
1.
2.
The refrigerant of the unit is not
enough;
The refrigerant of the unit is not
enough due to that the
installation pipe is longer.
3.Throttling service fails;
4.The outdoor ambient temperature
is too high.
1.
2.
Check the welding point to
confirm whether the unit has
leakage point, and then add
some refrigerant.
Add some refrigerant referring
to the installation user manual;
3.Replace the throttling service
(such as capillary, expansion
valve)
4.Normal protection.
48
The outdoor DC
fan motor fault
(upper fan motor)
1.The connecting wiring of the up
DC fan motor is loose;
2.The cord of the upper DC fan
motor fails;
3.The upper DC fan motor fails;
4.The drive circuit of the upper DC
fan motor fails;
5.The outdoor fan has been
blocked.
1.Reconnect the wiring of the up
DC fan motor;
2.Replace the upper DC fan
motor;
3.Replace the upper DC fan
motor;
4.Replace the driver board of
the fan motor;
5.Check the outdoor fan and
ensure the outdoor fan can
run normally.
96 Lacking of refrigerant The refrigerant of the unit is not
enough.
Discharge the refrigerant and
charge the refrigerant
referring to the rating label.
97
4-way valve
commutation failure
fault
1.The connecting wiring of the 4-
way valve coil is loose;
2.The 4-way valve coil fails;
3.The 4-way valve fails;
4.The driver board of the 4-way
valve fails.
1. Reconnect the wiring of the
4-way valve;
2. Replace the 4-way valve coil;
3. Replace the 4-way valve;
4.Replace the driver board of the
4-way valve.
Expansion valve E
(gas pipe)
sensor
fault
1. The wiring of the sensor for the
expansion valve E (gas pipe) is
connected loosely;
2. The sensor of the expansion
valve E (gas pipe) fails;
3. The sampling circuit fails.
1. Reconnect the wiring of the
sensor for the expansion valve
E (gas pipe);
2. Replace the sensor for the
expansion valve E (gas pipe);
3. Replace the outdoor control
board.
Expansion valve D
(liquid) pipe sensor
fault
1.The wiring of the sensor for the
expansion valve D (liquid pipe) is
connected loosely;
2.The sensor of the expansion valve
D (liquid pipe) fails;
3.The sampling circuit fails.
1. Reconnect the wiring of the
sensor for the expansion valve
D (liquid pipe);
2. Replace the sensor for the
expansion valve D (liquid pipe);
3. Replace the outdoor control
board.
50
53
57
Summary of Contents for 3PAMSHHQC18-MZO2
Page 12: ...3 OUTLINES AND DIMENSIONS 3 Outlines and dimensions 18K Unit in mm 8...
Page 15: ...42K Unit in mm 3 OUTLINES AND DIMENSIONS 11...
Page 26: ...7 REFRIGERANT CYCLE 7 Refrigerant cycle 18K 24K 22...
Page 29: ...8 WIRING DIAGRAM 24K Electric wiring diagram 1993419 F 25...
Page 30: ...8 WIRING DIAGRAM 36K Electric wiring diagram 2000947 H 26...
Page 31: ...8 WIRING DIAGRAM 42K Electric wiring diagram 2087381 B 27...