The correction factor of height between indoor unit and outdoor unit
To ensure correct unit selection, consider the farthest indoor unit.
NOTE:
1.
Above data is assuming that the height difference between indoor unit and outdoor unit is 0m.
2.
Be sure to minimize length of connection pipes to optimize performance. If the outdoor unit is installed higher
or lower than the indoor unit, it is necessary to apply height correction factor additionally to length correction
factor to calculate cooling/heating.
If outdoor unit is higher, correction should be applied to cooling capacity, if outdoor unit is lower, correction
should be applied to heating capacity.
Cooling
Heating
EL
Model
49ft
(15m)
74ft
(22.5m)
98ft
(30m)
123ft
(37.5m)
164ft
(50m)
197ft
(60m)
246ft
(75m)
262ft
(80m)
18K
1
.0
0.9
9
0.9
7
0.
95
0
.92
-
-
-
24K
0.99
1
.0
0.9
9
0.9
8
0.9
6
0.
94
-
-
36K
-
0.99
1
.0
0.9
9
0.9
8
0.9
6
0.
94
-
42K
-
-
0.99
1
.0
0.9
9
0.9
7
0.9
6
0.
94
EL
Model
49ft
(15m)
74ft
(22.5m)
98ft
(30m)
123ft
(37.5m)
164ft
(50m)
197ft
(60m)
246ft
(75m)
262ft
(80m)
18K
1.0
0.95
0.89
0.8
4
0.7
5
-
-
-
24K
1
.0
1
.0
0.9
7
0.9
4
0.8
7
0.8
0
-
-
36K
-
1
.0
1
.0
0.98
0.9
3
0.8
7
0.8
0
-
42K
-
-
1
.0
1
.0
0.96
0.9
1
0.8
7
0.8
2
Height difference
16ft (5m)
23ft (7m)
29.5ft (9m)
36ft (11m)
43ft (13m)
49ft (15m)
Factor
1
0.98
0.96
0.94
0.91
0.88
19
Summary of Contents for 3PAMSHHQC18-MZO2
Page 12: ...3 OUTLINES AND DIMENSIONS 3 Outlines and dimensions 18K Unit in mm 8...
Page 15: ...42K Unit in mm 3 OUTLINES AND DIMENSIONS 11...
Page 26: ...7 REFRIGERANT CYCLE 7 Refrigerant cycle 18K 24K 22...
Page 29: ...8 WIRING DIAGRAM 24K Electric wiring diagram 1993419 F 25...
Page 30: ...8 WIRING DIAGRAM 36K Electric wiring diagram 2000947 H 26...
Page 31: ...8 WIRING DIAGRAM 42K Electric wiring diagram 2087381 B 27...