8
. WIRING DIAGRAM
8.3 Common wiring
Max
.
Running
Current
(
A
):
REFER
TO
NAMEPLATE
Model
(Capacity:
Btu/h)
Power Supply
ELB
Power Source
Cable Size
Transmitting
Cable Size
Circuit
Breaker (A)
Rated Current
(A)
Nominal Sensitive
Current (mA)
18K
208/230V ~/60Hz
30
30
14AWG
Ground
16AWG
Ground
30
24K
208/230V ~/60Hz
30
30
12AWG
Ground
16AWG
Ground
30
36K
208/230V ~/60Hz
50
30
10AWG
Ground
16AWG
Ground
50
42K
208/230V ~/60Hz
50
30
10AWG
Ground
16AWG
Ground
50
●
Use cooper power supply wires.
●
Follow local codes and regulations when select field wires, and all the above are the minimum
wire size.
●
When transmitting cable length is longer than 49 ft. (15m), a larger wire size should be selected.
●
Install main switch and ELB for each system separately. Select the high response type ELB that
acts within 0.1second.
NOTE:
Electrical wiring diagram
NOTES:
1. For 18K model, there is no INDOOR UNIT C, D and E.
2. For 24K model, there is no INDOOR UNIT D and E.
3. For 36K model, there is no INDOOR UNIT E.
Recommended
w
ire
s
ize
Outdoor unit
Indoor unit A
Indoor unit B
Indoor unit
C
Terminal
Terminal B
Terminal C
Terminal
Terminal
Terminal
Power supply
SI
SI
SI
SI
SI
SI
SI
SI
SI
L
L
L
L
L
L
L
L
L
N
N
N
N
N
N
N
N
N
Power connecting cord
Power connecting cord
Power connecting cord
L2
L1
Outdoor unit
Indoor unit
SI
3(SI)
L
2(L)
N
1(N)
Power connecting cord
Note: For some indoor units
Indoor unit
D
Terminal D
Terminal
Power connecting cord
Indoor unit
E
Terminal E
Terminal
Power connecting cord
L
N
SI
34
Summary of Contents for 3PAMSHHQC18-MZO2
Page 12: ...3 OUTLINES AND DIMENSIONS 3 Outlines and dimensions 18K Unit in mm 8...
Page 15: ...42K Unit in mm 3 OUTLINES AND DIMENSIONS 11...
Page 26: ...7 REFRIGERANT CYCLE 7 Refrigerant cycle 18K 24K 22...
Page 29: ...8 WIRING DIAGRAM 24K Electric wiring diagram 1993419 F 25...
Page 30: ...8 WIRING DIAGRAM 36K Electric wiring diagram 2000947 H 26...
Page 31: ...8 WIRING DIAGRAM 42K Electric wiring diagram 2087381 B 27...