1
4
.TROUBLESHOOTING
Fault
code
Fault description
Possible
r
eason
s
f
or
a
bnormality
How to
d
eal
w
ith
Remarks
74 Indoor EEPROM
Data 2 fault
EE in MCU is fails, the unit
can run, but the function user
has set is ineffective.
Replace EE data in MCU.
81
Indoor ambient
Temperature
Sensor Fault
1. The cable of the room
temperature sensor is connect
loosely;
2. The room temperature sensor
fails;
3. The sampling circuit is abnormal.
1. Reconnect the cable of the
room temperature sensor;
2. Replace the room temperature
sensor;
3. Replace the indoor control
board.
83
Evaporator Middle
Temperature
Sensor Fault
1.The cable of the coil temperature
sensor of the evaporator fails;
2.The coil temperature sensor of
the evaporator fails;
3.The sampling circuit is abnormal.
1. Reconnect the cable of the
coil temperature sensor of the
evaporator;
2. Replace the coil
temperature sensor of the
evaporator;
3. Replace the indoor
control board.
FE
(254)
Communication
between main
control board &
Wired controller
Fault (display on
wired controller)
1. The wired controller and the
indoor control board are
connected loosely.
2. The sequence of the wiring
between the wired controller
to the indoor control board is
wrong;
3. The wiring between the
wired controller to the indoor
control board fails;
4. The wired controller is fails;
5. The indoor control board
is abnormal.
1.
2.
Reconnect the wiring between
the wired controller to the
indoor control board;
Replace the wiring between
the wired controller to the
indoor control board;
3. Replace the wiring between
the wired controller to the
indoor control board;
4. Replace the wired controller;
5. Replace the indoor control
Board.
ER
Communication
between main
control board
& display board
Fault (displays on
display board)
1.The wiring between the display
board to the indoor control
board is connected loosely;
2.The sequence of the wiring
between the display board to the
indoor control board is wrong;
3.The wiring between the display
board to the indoor control
board fails;
4.The display board fails;
5.The indoor control board fails.
1. Reconnect the wiring
between the display board
to the indoor control board;
2. Replace the wiring between
the display board to the
indoor control board;
3. Replace the wiring between
the display board to the
indoor control board;
4. Replace the display board;
5. Replace the indoor control
board.
58
Summary of Contents for 3PAMSHHQC18-MZO2
Page 12: ...3 OUTLINES AND DIMENSIONS 3 Outlines and dimensions 18K Unit in mm 8...
Page 15: ...42K Unit in mm 3 OUTLINES AND DIMENSIONS 11...
Page 26: ...7 REFRIGERANT CYCLE 7 Refrigerant cycle 18K 24K 22...
Page 29: ...8 WIRING DIAGRAM 24K Electric wiring diagram 1993419 F 25...
Page 30: ...8 WIRING DIAGRAM 36K Electric wiring diagram 2000947 H 26...
Page 31: ...8 WIRING DIAGRAM 42K Electric wiring diagram 2087381 B 27...