DIAGNOSTICS
The control records and displays a variety of diagnostic data to
assist with troubleshooting performance issues and fine-tuning
system efficiency. Press the
Diagnostics
button from the
Master Settings or Home screens to view the Diagnostic screen.
Figure 26 Diagnostic Screen
• Press the screen navigation arrows at the upper-right and
left of the screen to view each diagnostic parameter.
• Press the Error Log button to access the Error Log
(Figure 29) screen. To clear the Error Log, press the Reset
button then the Reset button again on the Clear All Error
Logs screen, then enter "1201" at the password prompt
screen, then press the Accept button to confirm.
Figure 27 Error Log Screen
Press the
Home
button to return to the Home screen.
NOTE: If a regeneration occurs while in the Diagnostic screen,
the unit will return to the main screen.
Parameter
Description
Flow Rate
Displays the current flow rate.
Peak Flow
*
Displays maximum flow rate of water along
with date and time of occurrence, since last
reset.
Totalizer
*
,
**
Displays total volume of water used since
last reset.
Last Regen
Displays when last regeneration occurred.
Reserve
Displays the reserve volume based on the
reserve type selected under master settings.
*This parameter is only available for meter
delayed regeneration type.
Software Version
Displays the software version installed on
the controller.
No of Regens
Displays how many manually and system
initiated regenerations the system has gone
through since last reset.
Regen Interval
Displays the average length of time between
regenerations based on the past four
regenerations.
Daily Usage
Displays average water usage for each day of
the week based on the usage on that day for
the past six weeks.
Usage Since Regen
Displays water usage since last regeneration.
Last Setting Change
Displays the date and time of the last update
to Master Settings.
NOTE*: Only Peak Flow and Totalizer can be changed - they
can be reset to zero.
NOTE**: Totalizer has a maximum value of 99,999,999. If this
number is reached, the Totalizer must be reset to zero
to continue tracking this value.
ALARMS AND ERRORS
If an error in valve or control function occurs, an alarm will
sound and the Home screen will display the Error
Alert button and the Alarm button .
Figure 28 Alarm and Error Alert
• Press the
Alarm
button to mute the alarm.
• Press the
Error Alert
button to view information about
the error.
Error Alert
Alarm
FLECK
5800/5810/5812 XTRI Service Manual • 15
Summary of Contents for FLECK 5800
Page 1: ...FLECK 5800 5810 5812 XTRI CONNECTED XTR2 SERVICE MANUAL pentair com...
Page 36: ...WATER CONDITIONER FLOW DIAGRAMS 5810 Upflow 36 FLECK 5800 5810 5812 XTRI Service Manual...
Page 37: ...WATER CONDITIONER FLOW DIAGRAMS 5810 Downflow FLECK 5800 5810 5812 XTRI Service Manual 37...
Page 44: ...INJECTOR FLOW DATA TR18755 REV B 44 FLECK 5800 5810 5812 XTRI Service Manual...