Model Name:
may include LXT, SXT, XTRI or XTRI
5800 - 0.75 ft
3
5800 - 1.0 ft
3
Test Model
5800 - 1.25 ft
3
5800 - 1.5 ft
3
5800 - 1.75 ft
3
5800 - 2.0 ft
3
"Rated Service Flow - gpm
with an upper collector"
9
11
11
10.5
12.5
12
Pressure Drop at Rated Service Flow
15
15
15
15
15
15
"Rated Capacity
(grains @ lbs. of salt)"
12,809 @ 2.81
21,051 @ 6.75
24,210 @ 11.25
17,930 @ 3.75
29,467 @ 9.0
33,889 @ 15.0
22,412 @ 4.7
36,833 @ 11.25
42,361 @ 18.75
26,895 @ 5.6
44,200 @ 13.5
50,833 @ 22.5
31,377 @ 6.6
51,567 @ 15.75
59,305 @ 26.25
35,860 @ 7.5
58,934 @ 18.0
67,778 @ 30.0
Rated Efficiency
(grains/lb. Salt @ lbs. of salt)
4,550 @ 2.81
4,780 @ 3.75
4,780 @ 4.7
4,780 @ 5.6
4,780 @ 6.6
4,780 @ 7.5
Maximum Flow Rate During
Regeneration (gpm)
1.7
2
2.4
2.4
3.5
3.5
Resin Volume - ft
3
Resin Type - 8% strong acid cation
0.75
1
1.25
1.5
1.75
2
Tank size
8" x 44"
9" x 48"
10" x 47"
10" x 54"
12" x 48"
12" x 52"
Backwash
8
8
8
8
8
8
Brine Draw & Slow Rinse
@ lb of Salt
50 @ 3.0
62 @ 6.75
78 @ 11.25
52 @ 3.75
70 @ 9.0
90 @ 15.0
43 @ 4.7
54 @ 11.25
65 @ 18.75
54 @ 5.6
70 @ 13.5
87 @ 22.5
61 @ 6.6
80 @ 15.75
100 @ 26.25
70 @ 7.5
91 @ 18.0
115 @ 30.0
Rapid Rinse
6
6
6
6
5
5
Fill @ lb of Salt
8 @ 3.0
18 @ 6.75
30 @ 11.25
10 @ 3.75
24 @ 9.0
40 @ 15.0
7 @ 4.7
15 @ 11.25
25 @ 18.75
8 @ 5.6
18 @ 13.5
30 @ 22.5
9 @ 6.6
21 @ 15.75
35 @ 26.25
10 @ 7.5
24 @ 18.0
40 @ 30.0
Operating Pressure:20 -125 psi or 1.4 – 8.8 kg/Centimeter
2
, Operating Temperature: 34 - 110° F or 1.1 – 43.3° C Acceptable Salt Type: Sodium Chloride
All Systems above tested at 35psi +/- 5 psi, pH of 7.5 +/- 0.5, Capacity Testing Flow Rate = 50% of the rated service flow rate for the various size systems
These water softener systems have been tested by WQA and conform to NSF/ANSI 44 for specific performance claims as verified
and substantiated by test data. The rated salt efficiencies above were also determined in accordance with NSF/ANSI 44 and
are only valid at the salt dosage referenced above. An efficiency rated water softener is a demand initiated regeneration (DIR)
softener which also complies with specific performance specifications intended to minimize the amount of regenerant brine
and water used in its operation. Efficiency rated water softeners shall have a rated salt efficiency of not less that 3350 grains
of total hardness exchanged per pound of salt (based on NaCl equivalency) (477 grams of total hardness exchanged per kilogram
of salt), and shall not deliver more salt than its listed rating. The rated efficiency of the water softener, the salt dosage at that
efficiency, the capacity at that salt dosage and that of the efficiency is only valid at the stated salt dosage. Efficiency is measured
by a laboratory test described in NSF/ANSI 44. The test represents the maximum possible efficiency the system can achieve.
Operational efficiency is the actual efficiency achieved after the system has been installed. It is typically less than the efficiency
due to individual application factors including water hardness, water usage, and other contaminants that reduce the water
softener’s capacity. These systems are not intended to be used for treating water that is microbiologically unsafe or of unknown
quality without adequate disinfection before or after the system. Refer to the system Installation and Service Manuals for set-up
and programming instructions.
Contact your local dealer for parts and service. See your owner’s manual for warranty information.
Tested and Certified by the WQA
to NSF/ANSI Standard 44 & 372 for
softener performance & lead free
compliance and CSA B483.1
Pentair Residential Filtration, LLC
13845 Bishops Drive Suite 200
Brookfield, Wisconsin 53005
PHONE: (262)-238-4400
Rev. F 7/16/19
C US
Valv
e Cy
cle T
ime
Se
tting
s (minut
es)
5800 PERFORMANCE DATA
FLECK
5800/5810/5812 XTRI Service Manual • 45
Summary of Contents for FLECK 5800
Page 1: ...FLECK 5800 5810 5812 XTRI CONNECTED XTR2 SERVICE MANUAL pentair com...
Page 36: ...WATER CONDITIONER FLOW DIAGRAMS 5810 Upflow 36 FLECK 5800 5810 5812 XTRI Service Manual...
Page 37: ...WATER CONDITIONER FLOW DIAGRAMS 5810 Downflow FLECK 5800 5810 5812 XTRI Service Manual 37...
Page 44: ...INJECTOR FLOW DATA TR18755 REV B 44 FLECK 5800 5810 5812 XTRI Service Manual...