• Master Settings
: Displays the Master Settings screen,
which allows you to fully program the valve.
• Brightness/Sound
: Displays the Brightness/Sound
screen, which allows you to adjust the backlight of the
control screen and allows you to mute the alarms of the
control.
NOTE: Due to the complexity of these settings and the
potential for errors, Master Settings should only be
accessed by your local water professional.
NOTE: Settings can not be accessed during a regeneration.
If a regeneration starts while in the settings menu,
the screen will return to the main screen and all
parameters will be voided.
Master Settings
The Master Settings screens include all configurable
parameters available in the control.
CAUTION
Improperly adjusting master settings may cause
the system to operate incorrectly. Before entering
master settings please contact your professional
water dealer.
From the Settings screen, press the Settings button .
A warning message appears.
Figure 11 Master Settings Warning Screen
Press
to continue to the Password screen or press
to
return to the Home screen.
The Password screen displays a numeric keypad.
Figure 12 Password Screen
• Enter the master settings password
1201
and press
to
continue to the main Master Settings screen, or press
to return to the Home screen.
After entering the correct password and pressing , the main
Master Settings screen is displayed.
.
Figure 13 Main Master Settings Screen
While in the Master Settings screens, press to save all
set parameters to a custom profile (see "NON-FACTORY
SETTINGS" on page 13 or press the
Home
button to return
to the Home screen.
Features of the Master Settings screens are described
below. See MASTER SETTINGS PROGRAMMING and MASTER
SETTINGS REFERENCE CHART for more detailed information.
• format
: Contains settings for Language, Units, Hardness
Units, Assistance Name, Assistance Phone, and
Assistance Interval.
• valve
: Contains settings for System, Valve, and
Regeneration Type.
• regen
: Contains settings for Regen Flow.
• relay
: Contains settings for Aux 1 and Aux 2 relays.
• meter
: (except for time clock systems) Contains settings
for Meter Types, emergency regeneration.
• settings
review
: Displays a summary of all programmed
settings.
MASTER SETTINGS PROGRAMMING
FLECK
5800/5810/5812 XTRI Service Manual • 9
Summary of Contents for FLECK 5800
Page 1: ...FLECK 5800 5810 5812 XTRI CONNECTED XTR2 SERVICE MANUAL pentair com...
Page 36: ...WATER CONDITIONER FLOW DIAGRAMS 5810 Upflow 36 FLECK 5800 5810 5812 XTRI Service Manual...
Page 37: ...WATER CONDITIONER FLOW DIAGRAMS 5810 Downflow FLECK 5800 5810 5812 XTRI Service Manual 37...
Page 44: ...INJECTOR FLOW DATA TR18755 REV B 44 FLECK 5800 5810 5812 XTRI Service Manual...