C US
Model Name:
may include SXT, XTRI or XTRI
5812 - 1.25 ft
3
5812 - 1.50 ft
3
5812 - 2.0 ft
3
test unit"
5812 - 3.0 ft
3
5812 - 4.00 ft
3
Maximum Rated Service Flow
(gpm) (W/upper collector)
14.2
14.8
19
21.9
24.3
Pressure Drop at Rated
Service Flow Rate (gpm)
13
15
15
15
15
Rated Capacity
(grains @ lbs. of salt)
21,604 @ 5.0
33,518 @ 11.25
38,243 @ 18.75
28,111 @ 6.0
43,614 @ 13.5
49,761 @ 22.5
37,482 @ 8.0
58,153 @ 18.0
66,349 @ 30.0
56,233 @ 12.0
87,229 @ 27.0
99,523 @ 45.0
74,964 @ 16.0
116,306 @ 36.0
132,698 @ 60.0
Rated Efficiency
(grains/lb. Salt @ lbs. of salt)
4,320 @ 5.0
4,690 @ 6.0
4,690 @ 8.0
4,690 @ 12.0
4,690 @ 16.0
Maximum Flow Rate During
Regeneration (gpm)
2.4
2.4
3.5
5
7
Resin Volume - ft
3
ResinType - 8% strong acid cation
1.25
1.5
2
3
4
Tank size
10" x 47"
10" x 54"
12" x 52"
14" x 65"
16" x 65"
Backwash
8
8
8
8
8
Brine Draw & Slow Rinse
@ lb of Salt
46 @ 5.0
58 @ 9.0
72 @ 18.75"
54 @ 6.0
68 @ 13.5
86 @ 22.5"
48 @ 8.0
62 @ 18.0
78 @ 30.0"
58 @ 12.0
76 @ 27.0
98 @ 45.0"
70 @ 16.0
84 @ 36.0
96 @ 60.0"
Rapid Rinse
6
6
6
6
6
Fill @ lb of Salt
14 @ 5.0
30 @ 11.25
50 @ 18.75"
16 @ 6.0
36 @ 13.5
60 @ 22.5"
11 @ 8.0
24 @ 18.0
40 @ 30.0"
8 @ 12.0
18 @ 27.0
30 @ 45.0"
11 @ 16.0
24 @ 36.0
40 @ 60.0"
Operating Pressure:20 -125 psi or 1.4 – 8.8 kg/Centimeter
2
, Operating Temperature: 34 - 110° F or 1.1 – 43.3° C Acceptable Salt Type: Sodium Chloride
All Systems above tested at 35psi +/- 5 psi, pH of 7.5 +/- 0.5, Capacity Testing Flow Rate = 50% of the rated service flow rate for the various size systems
These water softener systems have been tested by WQA and conform to NSF/ANSI 44 for specific performance claims as verified and substantiated
by test data. The rated salt efficiencies above were also determined in accordance with NSF/ANSI 44 and are only valid at the salt dosage referenced
above. An efficiency rated water softener is a demand initiated regeneration (DIR) softener which also complies with specific performance
specifications intended to minimize the amount of regenerant brine and water used in its operation. Efficiency rated water softeners shall have
a rated salt efficiency of not less that 3350 grains of total hardness exchanged per pound of salt (based on NaCl equivalency) (477 grams of total
hardness exchanged per kilogram of salt), and shall not deliver more salt than its listed rating. The rated efficiency of the water softener, the salt
dosage at that efficiency, the capacity at that salt dosage and that of the efficiency is only valid at the stated salt dosage. Efficiency is measured by
a laboratory test described in NSF/ANSI 44. The test represents the maximum possible efficiency the system can achieve. Operational efficiency
is the actual efficiency achieved after the system has been installed. It is typically less than the efficiency due to individual application factors
including water hardness, water usage, and other contaminants that reduce the water softener’s capacity. These systems are not intended to be
used for treating water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Refer to the
system Installation and Service Manuals for set-up and programming instructions.
Contact your local dealer for parts and service. See your owner’s manual for warranty information.
Tested and Certified by
the WQA to NSF/ANSI
Standard 44 & 372 for
softener performance
& lead free compliance
and CSA B483.1
Pentair Residential Filtration, LLC
13845 Bishops Drive Suite 200
Brookfield, Wisconsin 53005
PHONE: (262)-238-4400
Valv
e Cy
cle T
ime
Se
tting
s (minut
es)
5812 PERFORMANCE DATA
Rev. B 7/09/19
FLECK
5800/5810/5812 XTRI Service Manual • 47
Summary of Contents for FLECK 5800
Page 1: ...FLECK 5800 5810 5812 XTRI CONNECTED XTR2 SERVICE MANUAL pentair com...
Page 36: ...WATER CONDITIONER FLOW DIAGRAMS 5810 Upflow 36 FLECK 5800 5810 5812 XTRI Service Manual...
Page 37: ...WATER CONDITIONER FLOW DIAGRAMS 5810 Downflow FLECK 5800 5810 5812 XTRI Service Manual 37...
Page 44: ...INJECTOR FLOW DATA TR18755 REV B 44 FLECK 5800 5810 5812 XTRI Service Manual...