The following is a detailed overview of settings available
in Master Settings. Please see the MASTER SETTINGS
REFERENCE CHART for the complete set of values and ranges
available to program while in Master Settings.
Format Screen
From the main Master Settings screen (Figure 13) press the
format
button to display the Format screen.
Figure 14 Format Screen
• language
: Displays the language used on the control
(international version only): English, French, German,
Italian, Spanish, or Dutch.
• units
: Contains settings for the unit type (either US or
Metric) to be used in the control.
• hardness units
: Contains settings for hardness units
of measure (grains per gallon, mg/L or ppm, German
degrees, French degrees, or English degrees). Hardness
units are adjustable only if metric units are selected.
NOTE: Degree hardness units are converted to ppm upon
input. Degree inputs may be rounded up or down
to the nearest ppm equivalent.
• Press the screen navigation arrows at the upper-right
and left of the screen to navigate to the Assistance Name,
Assistance Phone, and Assistance Interval screens.
• Press
to save changes.
Valve Screen
From the main Master Settings screen (Figure 13) press the
valve
button to display the Valve screen.
Figure 15 Valve Screen
• system
: Displays the system type. Type 4 (single system)
is currently the only available selection.
• valve
: Contains settings to select the valve model
installed with the control.
• regen type
: Contains settings for the type of regeneration
to use for the system. Regeneration types are described
in detail below.
Regeneration Types
The XTRI control supports several different Regeneration
Types. The Regeneration Type defines the method of automatic
regeneration for the system. Each type is explained below.
Time Clock
Triggers a regeneration on a timed interval. The control will
initiate a regeneration cycle at the selected Regeneration Time
when the number of days since the last regeneration equals
the Day Override value. The Day Override can be set from 1 - 99
days as well as partial day intervals of 4, 8, 12, 16 and 20 hours.
Softener Immediate
Measures water usage and regenerates the system as soon
as the calculated system capacity is depleted. The control
calculates the system capacity by dividing the unit capacity by
the feed water hardness. Softener Immediate systems do not
use a reserve volume. The control will also start a regeneration
cycle at the programmed regeneration time if a number of days
equal to the Day Override pass before water usage depletes
the calculated system capacity. The Day Override parameter
default is OFF, and REGEN TIME will be grayed out unless the
day override value has been modified.
CAUTION
When setting the system for softener immediate
regeneration, setting the capacity to a value lower
than that of feed water hardness may cause the
system to constantly regenerate. If this occurs,
disconnect the motor from the control and correct
the capacity and feed water hardness values in
Master Settings.
Softener Delayed
Measures water usage and regenerates the system at the
selected Regeneration Time after the calculated system
capacity is depleted. The control calculates the system capacity
by dividing the unit capacity by the feed water hardness and
subtracting the reserve.
MASTER SETTINGS PROGRAMMING
(continued)
10 •
FLECK
5800/5810/5812 XTRI Service Manual
Summary of Contents for FLECK 5800
Page 1: ...FLECK 5800 5810 5812 XTRI CONNECTED XTR2 SERVICE MANUAL pentair com...
Page 36: ...WATER CONDITIONER FLOW DIAGRAMS 5810 Upflow 36 FLECK 5800 5810 5812 XTRI Service Manual...
Page 37: ...WATER CONDITIONER FLOW DIAGRAMS 5810 Downflow FLECK 5800 5810 5812 XTRI Service Manual 37...
Page 44: ...INJECTOR FLOW DATA TR18755 REV B 44 FLECK 5800 5810 5812 XTRI Service Manual...