MASTER SETTINGS REFERENCE CHART
CAUTION
Before entering Master Settings, please contact your local professional water dealer.
Screen Name
Parameters
Values
Notes
Format
Language
English, French,
German, Italian,
Spanish, Dutch
Changes the language to display screen text and button labels in the control (available with international
version of control only).
Units
U.S.
Metric
Changes system units and values across all parameters in the control. All programmed units and values
should be recalculated after adjusting this setting.
Hardness Units
Grains per gallon
mg/L or ppm
German degrees
French degrees
English degrees
Changes hardness units used in displaying hardness parameters and calculating system capacity and editing
exchange capacity and hardness settings.
Assistance Name
Free-form text
A - Z and space
Name of service provider to display when viewing the Assistance screen. 20 character limit.
Assistance Phone
Free-form text
0 - 9 and space
Phone number of service provider to display when viewing the Assistance screen. 20 character limit.
Assistance Interval
Month Based
Regen Based
1 - 60
1 - 2000
Off
Set to automatically display the Assistance screen after a certain number of months or regenerations.
Valve
System
4
System 4 (single system) is currently the only available selection.
Valve
5800
5810
5812
Select the type of valve to be installed.
Media Volume
0.25 - 999.00 ft3
1 - 9999 L
Used to calculate capacity.
Salt Dosage
3 - 18 lbs/ft3
50 - 290 g/L
Used to calculate capacity and refill time.
BLFC size
0.125 gpm
0.250 gpm
0.500 gpm
1.000 gpm
Brine Line Flow Control; Used to calculate refill time.
Regen. Type
Time Clock
Softener Immediate
Softener Delayed
Filter Immediate
Filter Delayed
Regeneration Types are described in detail on page 11.
Additional Valve screen parameters are dependent upon selected Regeneration Type. Not all parameters will
be displayed.
Softener Delayed regeneration type has four reserve options (Fixed %, Fixed Volume, Variable Reserve, Weekly
Reserve). The control will display additional configuration options depending on the selected reserve type.
Capacity
1 - 99 999 999
grains / grams / degrees
Only required on metered systems to calculate treated water capacity and reserve. Represents total system
capacity between regenerations.
Hardness
1 - 199 grains/gallon
1 - 1 999 mg/liter
x - x degrees
Only required on metered systems to calculate treated water capacity and reserve. Represents hardness of
untreated water.
Reserve
Fixed %
Fixed Volume
Weekly Reserve
Variable Reserve
Only available when Meter Delayed regeneration type is selected.
Selecting Fixed % or Fixed Volume will display additional configuration options.
Weekly Reserve is calculated based on average day of week's water usage.
Variable Reserve is calculated based on previous day's water usage.
Day Override
1 - 99 days
4, 8, 12, 16, 20 hours
Available to be programmed for all Regeneration Types.
Regen Time
12 / 24 hour clock
Required for Time Clock and delayed Regeneration Types. Set for immediate regeneration types only when a
Day Override is also set.
Volume Override
1 - 99 999 999 gallons / liters
Only displayed when Regeneration Type is Filter Immediate or Filter Delayed.
Regeneration
Regen. Flow
Upflow
Downflow
Downflow 2x Backwash
Filter
Custom Upflow/Downflow/Filter
Variable Refill
Cycle steps on the Home screen and during regeneration will change to reflect the cycle steps and order in
the selected Regenerant Flow.
Additional Regeneration screen parameters are dependent upon selected Regenerant Flow. Not all
parameters will be displayed.
Custom Upflow and Downflow allows for up to 20 programmable cycle steps.
Variable Refill calculates refill time based on Salt Dosage, Media Volume, and BLFC Size.
Time per cycle step can be programmed for all other Regenerant Flow options.
Relay Outputs
Aux 1/Aux 2
Cycle Based
Time Based
Volume Based
Alarm Based
Off
For Cycle Based relays, select the cycle steps on which the relays will turn on. For Time Based relays, two
start/end times will need to be selected for each relay. Relay times are based on total regeneration cycle time.
Volume Based relays can be programmed from zero gallons/liters to the full system capacity. Duration can be
set from zero seconds to two hours. Volume Based option is not available when Regeneration Type is set to
Time Clock. Alarm Based relays will turn on when an alarm condition is met, and will turn off when the alarm
is cleared.
Meter
Meter Type
.75 inch Turbine
.75 inch Paddle
1.00 inch Paddle
1.25 inch Turbine
1.50 inch Paddle
1.50 inch Turbine
2.00 inch Paddle
3.00 inch Paddle
Generic
Select the type of meter installed with the system. A Generic option is available if the installed meter does not
match any other selection. Selecting the Generic meter type requires setting the number of pulses per gallon
or liter to ensure proper metering.
Generic
1 - 999.9 /1 - 1500
pulses per gallon / liter
Only available when Generic meter type is selected.
Remote Regen
Remote Regen
1 - 255 seconds
Off
Select a value in seconds that the remote switch must be closed in order to trigger the regeneration.
NOTE: Some items may not be shown depending on control configuration. The control will discard any changes and exit Master Settings if any button is not pressed for five minutes.
FLECK
5800/5810/5812 XTRI Service Manual • 23
Summary of Contents for FLECK 5800
Page 1: ...FLECK 5800 5810 5812 XTRI CONNECTED XTR2 SERVICE MANUAL pentair com...
Page 36: ...WATER CONDITIONER FLOW DIAGRAMS 5810 Upflow 36 FLECK 5800 5810 5812 XTRI Service Manual...
Page 37: ...WATER CONDITIONER FLOW DIAGRAMS 5810 Downflow FLECK 5800 5810 5812 XTRI Service Manual 37...
Page 44: ...INJECTOR FLOW DATA TR18755 REV B 44 FLECK 5800 5810 5812 XTRI Service Manual...