8.2.4
Tx Link EQ Time Response (with Presets/Cursors) Startup and Testing
Prior to starting this test, take note of the following:
▪
This test uses AC fit methodology defined in the
PCIe CEM 5.0 Specification
for preset testing
at 32 GT/s. Testing at lower data rates uses Vb based methodology defined in respective
PCIe
Base Specifications
.
▪
To account for measurement noise, a tolerance of ±1.0 dB is used for measured preshoot and
de-emphasis that are defined as 0.0 dB in the
PCI Express Base Specification
.
▪
Due to measurement sensitivity having more impact on higher boost preset, a tolerance of
±1.5 dB is used for P10 preshoot.
▪
The designs are expected to not support any preshoot or de-emphasis on presets that define
0.0 dB for preshoot or de-emphasis. The allowed tolerance is to account for measurement
noise only.
The Anritsu MX183000A High-Speed Serial Data test software is used with the MX190000A test
application on the MP1900A BERT to perform the Tx link EQ time response test with presets or
cursors. The oscilloscope will also be used to capture waveforms for post processing analysis.
1.
Configure the oscilloscope as follows:
•
Averaging: OFF
•
Horizontal Scale: 6.25 µs/div (2M UI)
•
Max Bandwidth: 33 GHz