5 • DS0 Mapping
Model 6511RC Matrix Switch Administrators’ Reference Guide
36
Defining DS0 mappings using the command line interface (CLI)
To configure the time slots parameter, enter a text string specifying which time slot numbers will be used for
the channel. You must enter a text string that comprises the following elements:
•
Numerals—Use numerals (0, 1, 2, 3, 4, 5, 6, 7, 8, 9) to represent time slot numbers
•
Comma—Use the comma (,) to separate non-contiguous timeslots. For example, the string 1,7,15 repre-
sents three timeslots numbered 1, 7 and 15.
Defining DS0 mappings using the command line interface (CLI)
To define a new connection using CLI, you must enter text strings in the following format:
t1-e1:Port#:Slots/toH110:Port#:Slots/fromH110:Port#:Slots
•
t1-e1—The fixed format for E1 ports in the STM-1 hierarchy.
•
Port# (1–63)—Any of the 63 E1s available.
•
Slots (1–32)—E1 timeslots range from 1 through 32.
•
to H110:Port#—Indicates the H.110 port number and transmission from 6511RC to TDM midplane bus
Note
There are a maximum of 32 ports available for the TDM midplane bus. If
the port number selected is not within the range supported an error will be
generated.
•
Slots:—Number of H.110 slots (1–128). The range should have a maximum of 32 slots, this corresponds to
the maximum capacity of 32 slots per E1.
•
FromH.110: Port #–Indicates the H.110 port number and transmission from TDM midplane bus to
6511RC.
•
Slots—Number of H.110 slots (1–128). The range should have a maximum of 32 slots, this corresponds to
the maximum capacity of 32 slots per E1.
Note
You must define the same number of time slots for each side of the connec-
tion.In other words, the number of time slots defined for toH.110 must be the
same as the number of time slots defined for fromH.110.
To configure the time slots parameter, enter a text string specifying which time slot numbers will be used for
the channel. You must enter a text string that comprises the following elements:
•
Numerals—Use numerals (0, 1, 2, 3, 4, 5, 6, 7, 8, 9) to represent time slot numbers
•
Comma—Use the comma (,) to separate non-contiguous timeslots. For example, the string 1,7,15 repre-
sents three timeslots numbered 1, 7 and 15.
•
Dash (-)—Use the dash (-) to represent a series of contiguous timeslots. For example, the string 1-31 repre-
sents all timeslots between 1 and 31 inclusive (that is, time slot 1, time slot 31 and all time slots in between).
Summary of Contents for 6511RC
Page 4: ...Summary Table of Contents Model 6511RC Matrix Switch Administrators Reference Guide 4...
Page 8: ...Table of Contents Model 6511RC Matrix Switch Administrators Reference Guide 8...
Page 12: ...Model 6511RC Matrix Switch Administrators Reference Guide 2...
Page 16: ...About this guide Model 6511RC Matrix Switch Administrators Reference Guide 6...
Page 102: ...11 SNMP Model 6511RC Matrix Switch Administrators Reference Guide 92 SNMP window...
Page 158: ...15 SDH Model 6511RC Switch Matrix Administrators Reference Guide 148 SDH Configuration link...