Statistics
139
Model 6511RC Switch Matrix Administrators’ Reference Guide
15 • SDH
Path Signal Label Mismatch
A Path or VT connection is not correctly provisioned if a received Path or VT Signal Label mismatch occurs. A
received Signal Label is considered mismatched if it does not equal either the locally provisioned value or the
value ‘equipped non-specific’ (1 hex).
Note
Any received non-zero Signal Label is considered a locally provisioned value
of ‘equipped non-specific’. Only in-service, provisioned Path Terminating
equipment can detect mismatched Signal labels. It is considered provisioned
if it has been configured for a mapping and has been assigned signals to and
from which the mapping takes place.
Received Path Signal Label
Displays the received path signal label.
Path Trace Mismatch
Activated upon detection of mismatch in the path trace.
Received Path Trace
Displays received path trace message string (in Hex format).
Figure 76. SDH Near and Far end Statistics section
Statistics
The statistics windows shows current and historical statistics for near and far end interfaces (see
figure 76
).
Figure 77. Near End Section Statistics—Current
Summary of Contents for 6511RC
Page 4: ...Summary Table of Contents Model 6511RC Matrix Switch Administrators Reference Guide 4...
Page 8: ...Table of Contents Model 6511RC Matrix Switch Administrators Reference Guide 8...
Page 12: ...Model 6511RC Matrix Switch Administrators Reference Guide 2...
Page 16: ...About this guide Model 6511RC Matrix Switch Administrators Reference Guide 6...
Page 102: ...11 SNMP Model 6511RC Matrix Switch Administrators Reference Guide 92 SNMP window...
Page 158: ...15 SDH Model 6511RC Switch Matrix Administrators Reference Guide 148 SDH Configuration link...