![Patton electronics 6511RC Administrator'S Reference Manual Download Page 33](http://html1.mh-extra.com/html/patton-electronics/6511rc/6511rc_administrators-reference-manual_4025850033.webp)
Alarm System Overview window
23
Model 6511RC Matrix Switch Administrators’ Reference Guide
4 • Alarms
The 6511RC uses three methods to indicate an alarm condition:
•
Front panel LED and rear blade indications—The front panel ALARM LED and rear blade ALARM LED
uses the following three states to indicate the presence and severity of an alarm:
-
Off
—No alarm is active
-
Solid
—Minor alarm
-
Flashing
—Major alarm
Note
The 6511RC’s factory-default configuration is to consider all alarms to be
major (orange) ones, so unless you customize the alarms severity levels (see sec-
tion
“Alarm Severity Configuration”
on page 26), any alarm that occurs will
cause the ALARM LED to flash, indicating a major alarm—the LED will
never indicate a minor alarm.
Note
If both power supplies are functioning normally, the
POWER
LED will display
a solid light, but if one or more power supplies fail, the
POWER
LED will
flash.
Figure 12. Sample alarm indications
•
Management web page indication—The Alarms section (see
figure 12
) of the Alarm System Overview win-
dow (see
figure 11
on page 22) uses color-coded highlighting to indicate which alarms are active and the
severity levels of active alarms.
-
Red
: indicates that one or more
critical
(severity 4) alarms are active. When active, critical alarm notifica-
tions also appear as red highlighting on the Home window (see
figure 6
on page 14) and as a flashing red
star (see
figure 49
on page 98) on the System Status window (see
figure 48
on page 98).
-
Orange
: indicates that one or more
major
(severity 5) alarms are active. When active, major alarm notifications
also appear as orange highlighting on the Home window (see
figure 6
on page 14) and as an orange exclamation
mark (see
figure 49
on page 98) on the System Status window (see
figure 48
on page 98).
-
Yellow
: indicates that one or more
minor
(severity 6) alarms are active. When active, minor alarm notifi-
cations also appear as yellow highlighting on the Home window (see
figure 6
on page 14) and as a yellow
triangle (see
figure 49
on page 98) on the System Status window (see
figure 48
on page 98).
Summary of Contents for 6511RC
Page 4: ...Summary Table of Contents Model 6511RC Matrix Switch Administrators Reference Guide 4...
Page 8: ...Table of Contents Model 6511RC Matrix Switch Administrators Reference Guide 8...
Page 12: ...Model 6511RC Matrix Switch Administrators Reference Guide 2...
Page 16: ...About this guide Model 6511RC Matrix Switch Administrators Reference Guide 6...
Page 102: ...11 SNMP Model 6511RC Matrix Switch Administrators Reference Guide 92 SNMP window...
Page 158: ...15 SDH Model 6511RC Switch Matrix Administrators Reference Guide 148 SDH Configuration link...