System Parameters window
105
Model 6511RC Matrix Switch Administrators’ Reference Guide
12 • System
Running Since Last Boot (sysUpTime)
This SNMP variable represents the time since the network management portion of the system was last re-
initialized.
System Manager (sysContact)
This SNMP variable represents the textual identification of the contact person for this managed node, which
may include information on how to contact this person as defined by specification RFC1213.MIB. The maxi-
mum length of this field is 256 octets.
Module Name (sysName)
This is “An administratively assigned name for this managed node. By convention, this is the node’s fully-
qualified domain name.” (RFC1213.MIB).
Physical Location (sysLocation)
“The physical location of this node (e.g., telephone closet, 3rd floor).” (RFC1213.MIB).
Background Image (boxBackgroundFlag)
The following options are available:
•
disableGraphics(0)—When this option is selected, graphics on WWW pages will not be displayed. This
results in faster page display times, but may make it more difficult to navigate WWW sites that rely heavily
on graphics.
•
enableGraphics(1)—When this option is selected, graphics on WWW pages are displayed.
•
disableWeb(2)—When this option is selected, access to the WWW pages is denied for everyone.
Monitor Privilege (boxMonitorPrivilege)
Specifies the privileges given to the monitor user. Privileges can be removed or additional write access can be
given beyond read-only access. The following options are available:
•
none(0)—The monitor user can not log in.
•
read only(2)—This is the default setting. The monitor user can view but not change any parameters. Mon-
itor can not view passwords.
•
writeUser(18)—Not supported.
•
writeUserlp(50)—The monitor user can change all parameters—except passwords— IP links.
•
writeUserlpWan(114)—The monitor user can change all parameters—except passwords— IP, and T1/E1.
•
writeUserlpWanSystem(242)—The monitor user can change all parameters—except passwords— IP, T1/
E1, System, and System Log links.
•
writeUserlpWanSystemUpload(498)—The monitor user can change all parameters—except passwords—
IP, T1/E1, System, and System Log links. The monitor user can also load firmware updates into the Matrix
Switch.
Front Handle Reset (TBD)
This parameter determines how the 6511 will behave when you unlock the topmost front handle.
Summary of Contents for 6511RC
Page 4: ...Summary Table of Contents Model 6511RC Matrix Switch Administrators Reference Guide 4...
Page 8: ...Table of Contents Model 6511RC Matrix Switch Administrators Reference Guide 8...
Page 12: ...Model 6511RC Matrix Switch Administrators Reference Guide 2...
Page 16: ...About this guide Model 6511RC Matrix Switch Administrators Reference Guide 6...
Page 102: ...11 SNMP Model 6511RC Matrix Switch Administrators Reference Guide 92 SNMP window...
Page 158: ...15 SDH Model 6511RC Switch Matrix Administrators Reference Guide 148 SDH Configuration link...