13 • System Log
Model 6511RC Matrix Switch Administrators’ Reference Guide
118
SYSTEM LOG (configuration) window
Min Priority for SysLog Daemon (syslogDaemonPriority)
System messages which have a priority equal to or greater than this setting will be sent to the syslog daemon
defined by the SysLog Daemon IP Address (syslogDaemonIP).
•
priorityVerbose(5)
•
priorityDebug(10)
•
priorityInfo(20)
•
priorityOddity(40)
•
priorityService(60)
•
prioritySystem(80)
•
priorityDisable(1000)
Min Priority for Console RS-232 (syslogConsolePriority)
System messages which have a priority equal to or greater than this setting will be sent directly to the RS-232
control port (RJ-45 connector labeled “Config”) on the front panel of the 6511RC. Messages will be sent
regardless of the current operating state of the RS- 232 configuration port. The lower the number next to the
priority listed below, the more details system logging will provide. Selecting priorityVerbose will generate the
most messages, while selecting priorityDisable will turn off all messages.
•
priorityVerbose(5)
•
priorityDebug(10)
•
priorityInfo(20)
•
priorityOddity(40)
•
priorityService(60)
•
prioritySystem(80)
•
priorityDisable(1000)
Min Priority for Flash Storage (syslogFlashPriority)
System messages which have a priority equal to or greater than this setting will be permanently stored in the
Flash PROM. Due to being permanent memory, the Flash memory eventually becomes filled. When this
occurs, the memory must be cleared before accepting more messages. Some maximum number of messages
may be stored in the Flash PROM before this storage area must be cleared.
•
prioritySystem(80)—Flash PROM will be used to store system-level messages.
•
priorityDisable(1000)—No messages will be stored.
Min Priority for SNMP Trap Daemon (syslogTrapPriority)
System messages which have a priority equal to or greater than this setting will be sent to the SNMP Trap Dae-
mon IP Address (syslogTrapIP). The lower the number next to the priority listed below, the more details sys-
tem logging will provide. Selecting priorityVerbose will generate the most messages, while selecting
priorityDisable will turn off all messages.
•
priorityVerbose(5)
Summary of Contents for 6511RC
Page 4: ...Summary Table of Contents Model 6511RC Matrix Switch Administrators Reference Guide 4...
Page 8: ...Table of Contents Model 6511RC Matrix Switch Administrators Reference Guide 8...
Page 12: ...Model 6511RC Matrix Switch Administrators Reference Guide 2...
Page 16: ...About this guide Model 6511RC Matrix Switch Administrators Reference Guide 6...
Page 102: ...11 SNMP Model 6511RC Matrix Switch Administrators Reference Guide 92 SNMP window...
Page 158: ...15 SDH Model 6511RC Switch Matrix Administrators Reference Guide 148 SDH Configuration link...