13 • System Log
Model 6511RC Matrix Switch Administrators’ Reference Guide
114
SYSTEM LOG main window
NVRAM. The System Log (Non-Volatile Memory window is described later in this chapter
“System Log—
Non-Volatile Memory window”
on page 120
Figure 58. Parameters section of the System Log main window
System Log parameters
The following sections describe the System Log parameters (see
figure 58
).
SysLog Daemon IP Address(syslogDaemonIP)
The IP address of a host computer system which is running a syslog daemon. System messages with a priority
greater than or equal to the configurable syslogDaemonPriority will be sent to this IP address (see section
“Pri-
ority”
on page 117).
SNMP Trap Daemon IP Address (syslogTrapIP)
The IP address of a host system which is running a SNMP trap daemon. SNMP Trap messages with a priority
greater than or equal to the configurable syslogTrapPriority will be sent to this IP address.
Min Priority for SysLog Daemon (syslogDaemonPriority)
System messages which have a priority equal to or greater than this setting will be sent to the syslog daemon
defined by the SysLog Daemon IP Address (syslogDaemonIP).
•
priorityVerbose(5)
•
priorityDebug(10)
•
priorityInfo(20)
•
priorityOddity(40)
•
priorityService(60)
•
prioritySystem(80)
•
priorityDisable(1000)
Min Priority for Console RS-232 (syslogConsolePriority)
System messages which have a priority equal to or greater than this setting will be sent directly to the RS-232
Config control port (RJ-45 connector labeled “Config”) on the front panel of the 6511RC. Messages will be
sent regardless of the current operating state of the RS-232 configuration port. The lower the number next to
Summary of Contents for 6511RC
Page 4: ...Summary Table of Contents Model 6511RC Matrix Switch Administrators Reference Guide 4...
Page 8: ...Table of Contents Model 6511RC Matrix Switch Administrators Reference Guide 8...
Page 12: ...Model 6511RC Matrix Switch Administrators Reference Guide 2...
Page 16: ...About this guide Model 6511RC Matrix Switch Administrators Reference Guide 6...
Page 102: ...11 SNMP Model 6511RC Matrix Switch Administrators Reference Guide 92 SNMP window...
Page 158: ...15 SDH Model 6511RC Switch Matrix Administrators Reference Guide 148 SDH Configuration link...