![Patton electronics 6511RC Administrator'S Reference Manual Download Page 116](http://html1.mh-extra.com/html/patton-electronics/6511rc/6511rc_administrators-reference-manual_4025850116.webp)
12 • System
Model 6511RC Matrix Switch Administrators’ Reference Guide
106
System Parameters window
•
enable(1)—When someone opens (unlocks) the top front handle the Model 6511 module will reboot as
follows:
–
When the switch is opened, the blue LED begins flashing ON/OFF every 2 seconds.
–
After 13 seconds, the unit will reboot.
Note
Opening the front handle triggers the reboot process described above. Once
you open the handle, you should immediately close it again before the mod-
ule actual reset occurs.
•
disable(0)—The 6511 will NOT restart when someone unlocks the topmost front handle.
SNMP and HTTP Parameters
This portion of the System Parameters window, shown in
figure 53
on page 104, provides the following infor-
mation about the SNMP version and the HTTP accessibility.
Version (boxSnmpVersion)
This parameter selects the SNMP version number supported by this unit. Select snmpv1(1) only, SNMP2 is
not currently supported.
Superuser Password (boxSnmpMasterPassword)
This parameter defines the password that provides superuser access via SNMP and HTTP to the Matrix Switch
web management interface. Logging on as Superuser gives you read access to all management information and
modify access to all Matrix Switch configurable parameters. The password may not exceed 64 octets (charac-
ters).
User Password (boxSnmpMonitorPassword)
This parameter defines the password that provides monitor access to the Matrix Switch web management
interface. Logging on with monitor access gives you read-only access to a limited selection of management
information. Certain parameters displayed for superuser access are hidden to user (monitor) access.
Summary of Contents for 6511RC
Page 4: ...Summary Table of Contents Model 6511RC Matrix Switch Administrators Reference Guide 4...
Page 8: ...Table of Contents Model 6511RC Matrix Switch Administrators Reference Guide 8...
Page 12: ...Model 6511RC Matrix Switch Administrators Reference Guide 2...
Page 16: ...About this guide Model 6511RC Matrix Switch Administrators Reference Guide 6...
Page 102: ...11 SNMP Model 6511RC Matrix Switch Administrators Reference Guide 92 SNMP window...
Page 158: ...15 SDH Model 6511RC Switch Matrix Administrators Reference Guide 148 SDH Configuration link...