E
Auxiliary Power Supply Load Requirements
This tables lists the auxiliary power supply requirements for the 890 units and ancillary equipment,
assuming normal operating conditions with maximum SMPS and fan loads.
Item
Load Requirements
Item
Load Requirements
Tech Cards - Communications
8903/DN : DeviceNet
1.3W
8903/IP : Ethernet/IP
1.6W
8903/PB : Profibus
2.3W
8903/M1 : Mark Registration 1W from +5V supply, plus up
to 3W from +24V supply
when an encoder is connected
8903/CN : ControlNet
1.3W
8903/PN : Profinet
1.6W
8903/CB : CANOpen
1.3W
8903/FA : Firewire 1394A
0.7W
8903?IM : Modbus/TCP
1.6W
8903/FB : Firewire 1394B
2W
Keypad
6901 Keypad
1W
6911 Keypad
1W
Worked Examples
To calculate the total requirement for an 890CS Frame D fitted with a 6511 keypad:
Power = 24 + 10.2 (fan load) + 0.9 = 35.1W, Input Current @ +24V = 35.1 / 24 = 1.463A
To calculate the total requirement for an 890CD Frame D fitted with a 6511 keypad and Profibus Tech Card:
Power = 20 + 0.9 + 2.3 = 23.2W, Input Current @ +24V = 23.2 / 24 = 0.967A
IMPORTANT
The 890's in24V SMPS has a 3A current limit which is used during start-up.
In a system containing ten 890 units for example, the initial loading will be 10 x 3A for approximately 50ms during
start-up, i.e. 30A. Consequently, the customer auxiliary SMPS +24V power supply must be able to over-load for a