Programming
Page
D-224
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D
8
9
10
A
B
C
D
E
1
2
3
4
5
6
7
PREF
Name
Block
Type
Range
Default
ro\rw
Notes
101.11
REVERSE
REFERENCE
BOOL
0 : FALSE
1 : TRUE
FALSE ro
Output
101.12
LOCAL SETPOINT
REFERENCE
REAL
_.xx
0.00 %
ro
Output
101.13
LOCAL REVERSE
REFERENCE
BOOL
0 : FALSE
1 : TRUE
FALSE ro
Output
101.15
FWIRE SETPOINT
REFERENCE
REAL
_.xx
0.00 %
ro
Output
101.16
SPEED DEMAND
REFERENCE
REAL
_.x
0.0 Hz
ro
Output
102.01
RUN STOP MODE
REFERENCE STOP
ENUM
0 : RUN RAMP
1 : COAST
2 : DC INJECTION
3 : STOP RAMP
RUN RAMP
rw
102.02
STOP TIME
REFERENCE STOP
REAL
0.0 to 600.0 s
10.0 s
rw
102.03
STOP ZERO SPEED
REFERENCE STOP
REAL
0.00 to 100.00 %
0.10 %
rw
102.04
STOP DELAY
REFERENCE STOP
REAL
0.000 to 30.000 s
0.500 s
rw
102.05
FAST STOP MODE
REFERENCE STOP
ENUM
0 : RAMP
1 : COAST
RAMP rw
102.06
FAST STOP LIMIT
REFERENCE STOP
REAL
0.0 to 3000.0 s
30.0 s
rw
102.07
FAST STOP TIME
REFERENCE STOP
REAL
0.0 to 600.0 s
0.1 s
rw
102.08
FINAL STOP RATE
REFERENCE STOP
REAL
l l 1 to l 4800 Hz/s
1200 Hz/s
rw
103.01
SETPOINT
REFERENCE JOG
REAL
-100.00 to 100.00 %
10.00 %
rw
103.02
ACCEL TIME
REFERENCE JOG
REAL
0.0 to 3000.0 s
1.0 s
rw
103.03
DECEL TIME
REFERENCE JOG
REAL
0.0 to 3000.0 s
1.0 s
rw
105.01
STALL TIME
STALL TRIP
REAL
0.1 to 3000.0 s
480.0 s
rw
3
105.02
STALL LIMIT
STALL TRIP
REAL
50.00 to 150.00 %
100.00 %
rw
105.03
STALL LIMIT TYPE
STALL TRIP
ENUM
0 : TORQUE
1 : CURRENT
2 : TRQ OR CURRENT
TRQ OR
CURRENT
rw