Programming Your Application
6-12
650G AC Drive
MMI Parameters Table
Display
Parameter
Description
Range
Default
ENC SPEED
SCALE
F
This parameter
allows the output
"speed" to be scaled
to any value the user
requires. With a
default value of
1.00, the output
"speed" is measured
in revs per second.
Changing the ENC
SPEED SCALE value
to 60.00 will provide
an output in revs per
minute.
To provide an output
in percent of the
motor maximum
speed, where
maximum speed is
the maximum speed
your motor will run
in rpm, the ENC
SPEED SCALE
parameter should be
set to the result of:
6000
maximum speed (rpm)
0.00 to 300.00
1.00
ENC SPEED
F
Speed feedback, in
units defined by the
ENC SPEED SCALE
parameter.
—
.x
—
.x