SINGLE ZONE connection with a 1K
W
EOL resistor
(N.C. and N.O. contacts)
address 208, key [
MEM
] = "off" (default)
key [10] = "off " (default)
key [11] = "off " (default)
SINGLE ZONE connection with a 1K
W
EOL resistor, tamper recognition
(N.C. contacts)
address 208, key [
MEM
] = "off "
key [10] =
key [11] =
Tamper fault transmits separate code.
ADVANCED TECHNOLOGY ZONE connection, 2 zones with zone resistors, 1 EOL resistor (1K
OHM
)
tamper (open) recognition, wire fault (short circuit) recognition (N.C. contacts)
address 208, key [
MEM
] = "off"
key [10] =
key [11] =
address 210, key [8] = "on"
Each zone transmits a separate alarm code.
Tamper/wire fault transmits a separate alarm code, indicated by fast
flashing zone light on keypad, and displayed in
Espload.
ADVANCED TECHNOLOGY ZONE connection, 1 zone resistor
(without EOL), tamper recognition (N.C. contacts)
address 208, key [
MEM
] = "on"
key [10] =
key [11] =
address 210, key [8] = "on"
Tamper fault transmits separate code.
TAMPER/WIRE FAULT DEFINITIONS AND OPTIONS
When using 2 zone resistors, the panel offers four possible definitions for tamper/wiring recognition,
independent of zone definition.
"Tamper/wire” disabled
(Address 208, Key [10] "off", Key [11] "off")
Tamper/wiring failure recognition is disabled.
"Trouble" enabled
(Address 208, Key [10] "off", Key [11] "on")
Tamper/wiring failure will generate an alarm, when armed. A trouble report code will be sent to the central
when disarmed.
"Silent alarm" enabled
(Address 208, Key [10] "on", Key [11] "off")
Tamper/wiring failure will generate a silent alarm (no siren) when the system is disarmed. Alarm and
trouble report codes will be sent to the central.
"Audible alarm" enabled
(Address 208, Key [10] "on", Key [11] "on")
Tamper/wiring failure will generate an audible alarm (siren). Alarm and trouble report codes will be sent
to the central.
IM728-738
9
See "Tamper/wire Fault Definitions
and Options"
See "Tamper/wire Fault Definitions
and Options"
See "Tamper/wire Fault Definitions
and Options"