![background image](http://html1.mh-extra.com/html/paradox/esprit-728/esprit-728_installation-manual_3612052022.webp)
Beep on exit delay
(Address 208)
Key [12] "on" = the keypad will sound on exit delay (except when in “stay” arming). Frequency of inter-
mittent beeps increases during the last 10 seconds of the exit delay period.
Zone restore transmission
(Address 208)
Key [
BYP
] "off " = If zone is closed, restoration code will be transmitted after "bell cut-off".
Key [
BYP
] "on" = Restoration code transmitted as soon as zone is closed.
Silent zones are always restored as soon as they are closed.
Zones with EOL resistors
(Address 208, key [
MEM
])
See "Loop configuration and zone connections" pages 8-9.
Always report disarm
(Address 208)
Key [
TRBL
] "off " = always reports disarm codes.
Key [
TRBL
] "on" = reports disarm code only after alarm.
Exclude power failure from trouble display
(Address 210, key [2
ND
])
Key ="on": Power failure will not make the [
TRBL
] key flash.
This trouble condition may still be viewed after pressing [
TRBL
].
“Associated zone” deactivation:
(Address 210, key [1])
Key = “on”: Disables burglar alarm zone associated with fire zone. Wire fault on the fire zone (fire trou-
ble) will not cause an alarm on the associated burglar zone.
Panel
Fire Zone
Associated zone
728
3
4 (ATZ)
738
3
9 (ATZ)
Arming Options
Auto arm
(Address 210, Key [2])
Key ="off ": When system auto arms (on time or "no movement"), "regular" arming will take place (if all
zones are closed).
Key ="on": When system auto arms (on time or “no movement”), "
STAY
" arming will take place (if all
zones are closed). If zone partitioning is programmed (address 206, key [8]), System “A” will
arm. (See also "Auto arming" p 22.)
No tamper bypass
(Address 210, key [6])
Key ="off ": Device tamper will not follow zone bypass.
Key ="on": Device tamper will follow zone bypass.
Advanced Technology Zoning (ATZ)
(Address 210, key [8])
Key = “on” Permits the use of two zone resistors per zone input. Each zone can transmit a separate
alarm that can each transmit its own alarm.
Key = “off” Single zone per zone input.
Audible trouble warning
(Address 210, Key [9])
Key ="on": Trouble conditions cause intermittent audible trouble warning on keypad. To silence, push [
TRBL
].
20 sec. delay before alarm transmission
(Address 210, Key [10])
Key ="on": The first time an alarm is generated, there will be a twenty (20) second delay before reporting
begins. During the waiting period, system disarm will cancel all pending reports.
IM728-738
20