KEY ACCESS PROGRAMMING
Programs features quickly, without entering addresses or section numbers.
To activate “key access programming”, press [
ENTER
], followed by installer, master or user code 1. (Code
required depends on the feature you wish to access - see below.) Then press the key corresponding to
the desired feature. Press [
ENTER
] or [
CLEAR
] to exit.
key
[9]
"Auto arming" time program
(accessible to master and user 1 only)
Key [9] flashes. Enter two digits (00 to 23) for hours + 2 digits (00 to 59) for minutes.
[
MEM
]
"Panel time" and clear "trouble 8"
(all 3 codes)
Key [
MEM
] flashes. Enter two digits (00 to 23) for hours + 2 digits (00 to 59) for minutes.
[
BYP
]
Test report
(all 3 codes)
Reporting is enabled at address 206 keys [11], [12]. A value must be entered at address 175,
and both telephone and account numbers must be programmed.
[
TRBL
]
Call Espload via telephone
(all 3 codes)
Panel identifier, PC password (addresses 001-004) and computer telephone number
(addresses 060-067) must be programmed.
[
AWAY
]
Answer Espload
(all 3 codes)
This feature is available when using the ADP-1 adapter. In Espload, "blind dial" must be
activated in "modem setup" section, and panel phone number must be programmed (works also
without ADP-1).
[
STAY
]
Cancel communication attempts
(master code and user 1 can only stop calls from/to Espload)
Until next reportable event
(installer code - all communications)
[2], [6]
Installer test mode
(installer code only)
In installer test mode, a confirmation beep (intermittent) indicates test is "on", a "rejection" beep (long)
indicates test is "off". The bell will squawk during walk testing to indicate opened, functional zones.
[2], [9]
“Auto arming” time program
(installer code only)
(Same as key [9] above)
When communicating with Espload, it is impossible to enter programming mode.
Paradox Security Systems - Graphic Dept. - PRINTED IN CANADA
IM728-738
29
WARRANTY
Warranty conditions for the
ESPRIT may vary from country to country. Please consult your local
dealer for complete warranty information. In all cases, the warranty does not cover malfunctions
arising from installer error or failure to follow installation/operation instructions, nor does it apply to
damages due to causes beyond the control of Paradox Security Systems, such as lightning, exces-
sive voltage, mechanical shock or water damage.
LIABILITY
Under no circumstances shall Paradox Security Systems be held liable for any direct or indirect
damages, loss of anticipated profits, loss of time, or any other losses incurred by the buyer in con-
nection with the purchase, installation, operation or failure of this product.
WARNING
This security system should undergo frequent testing. However, despite regular testing, and due to,
but not limited to, criminal tampering or electrical disruption, it is possible for this product to fail to
perform as expected.