IM728-738
19
Auto zone shutdown
(Address 206, key [
TRBL
] "on")
Key [
TRBL
] "on" =
zones that initiate 4 consecutive alarms during the same armed period will be auto-
matically bypassed. (Zones must be bypass-enabled at address 236.) After a zone
has been bypassed, the panel can send a "partial arming" report to the central (if
programmed to do so at address 187).
Note: Once auto zone shutdown has been enabled, it will either be activated after 4 "zone closure"
restoration reports or 4 "bell cut-off " restoration reports, depending on which type of alarm restora-
tion code has been activated at address 208, key [
BYP
].
Automatic event buffer transmission
(Address 208, key [2
ND
])
Key [2
ND
] "on" = system will dial the computer telephone number programmed in Section 00 and 01
(addresses 060-067) to upload the contents of the event buffer to the PC. (Espload must be in "wait for
call" mode.) The system will make two attempts to call the PC when the event buffer reaches 50%
capacity. If communication is established, the system will then proceed to report the contents of the event
buffer to the PC. Should transmission be interrupted before the complete contents of the buffer can be
transmitted, or if after two attempts, communication is not established, the system will wait until the event
buffer is full, before attempt to communicate with the central again.
If communication is established, the system will then proceed to report the contents of the event buffer to
the PC. If after two attempts, communication is not established, each subsequent new event will erase
the oldest event in the buffer, until the event buffer once again reaches 50% capacity.
Enable keypad panic signals
(Address 208)
Key [1] "on" = Panic 1 (keys [1] and [3]) enabled
Key [2] "on" = Panic 2 (keys [4] and [6]) enabled
Key [3] "on" = Panic 3 (keys [7] and [9]) enabled
Keypad panic options
(Address 208)
Key [4] "off " = Panic 1 silent
Key [5] "off " = Panic 2 silent
Key [6] "off " = Panic 3 silent
Key [4] "on" = Panic 1 audible
Key [5] "on" = Panic 2 audible
Key [6] "on" = Panic 3 fire
Silent operation
When panic keys [1] and [3], OR [4] and [6], OR [7] and [9] are pushed simultaneously for 2 seconds, a
single confirmation beep is sounded, codes programmed at addresses 184, 185, and 186 are transmitted
and the alarm latches, flashing the keypad "armed" light until reset by a user code.
Audible operation
When panic keys are pushed in addition to alarm codes being transmitted, the alarm output (bell/siren)
will activate until reset by a user code or until the bell cut-off time (address 250) expires.
Fire operation
Same as audible operation except that bell/siren output will be pulsed (intermittent "on"/"off ").
"One key" arming enable
(Address 208)
Key [7] "on" = Pushing key [10] for 2 seconds "full" arms system.
Key [8] "on" = Pushing key [11] for 2 seconds "stay" arms system.
User/access code length
(Address 208)
Key [9] "off " = 6 digit user/access codes and installer code.
Key [9] "on" = 4 digit user/access codes and installer code.
Tamper/wire fault definitions
(Address 208)
Note:
If key [10] and key [11] are both "off ", this means that tamper and wire faults will not be recog-
nized. See "Loop configuration and zone connections" page 8-9, "Tamper/Wire Fault Definition
and Options", page 9, and "Tamper/wire Fault Definition table" in the "Programming Guide".