IM728-738
Digital Communicator:
Compatible with most worldwide telecommunication standards.
Reporting formats:
Pulse: Ademco slow (10BPS), Silent Knight fast, Sescoa (20 BPS) Radionics,
Radionics with parity (40 BPS), 1400Hz - 1800Hz (10 BPS)
DTMF: Contact ID, Ademco Express, “No handshake” DTMF format. (Pager)
True Dial tone detection and telephone line monitoring.
Fully up/downloadable with PC.
Regular, Split and Double reporting modes.
“Delay before alarm transmission” option.
Espload
Upload/download PC software.
Provides full up/download within 45 seconds.
Permits creation of unlimited number of account and panel default files.
Powerful "monitoring" mode supervises all panel activity.
"Scheduler" activates panel features at preprogrammed intervals.
"Batch" mode carries out tasks following panel call.
Accessory Modules:
SRI 18: 18 PGM outputs, 708: Secondary Digital Dialer (UL listed)
708DV: DVACS communicator (Canada only), Esprint: Parallel printer interface (not UL listed).
Keypads:
616, 626, 629 and 633 (LED) keypads. 639 and 640 (LCD) keypads, PS1 bedside remote. (For UL sys-
tems use only 616, 626, 640 or PS1.)
Current Consumption:
(measured with battery connected, without AC and with 1K
W
resistor on bell and 1K
W
resistor on zones.)
738 control panel:
25mA
DC
633 LED keypad:
15mA
DC
Typical
728 control panel:
25mA
DC
35mA
DC
Maximum
616/626 LED keypads:
15mA
DC
Typical
PS1 bedside remote:
15mA
DC
Typical
30mA
DC
Maximum
20mA
DC
Maximum
629 access control keypad:
30mA
DC
Typical
SRI-18: 50mA
DC
Typical
55mA
DC
Maximum
639/640 LCD keypads:
20mA
DC
Typical
45mA
DC
Maximum
LOCATION AND MOUNTING
Remove the printed circuit board, mounting hardware and keypad from the packaging inside the panel
box. Press the four white nylon mounting studs into cabinet from the back before mounting the
cabinet. Before mounting circuit board on the back of the cabinet, pull all cables into cabinet and prepare
them for connection.
Select a control panel installation site that is not easily accessible to intruders. Leave at least 2” around
the panel box to permit adequate ventilation/heat dissipation. Installation location should be dry, close to
an AC source, ground connection and a telephone line connection.
6