IM728-738
16
Typical PGM (Programmable Output) Programming
Note: For other PGM operations, i.e. home automation, programmable controller, false alarm reduction,
etc., use
Espload software to provide programming codes (over 1000 options available). (If other
programming options are needed, fax your requests to Paradox Technical Support at 514-491-2313.)
System Options
(Default = "off" for addresses 200-242)
Feature select programming
"ON”/"OFF" status of the key lights determines feature selection.
In programming mode, enter 3 digit memory address (200 to 242).
To save entries, press [
ENTER
]. To exit programming mode press [
CLEAR
].
Code priority
(Addresses 200 to 204)
Keys [1] to [12] represent the corresponding code number. Key [1] represents user code 1, [2] = 2, [3] =
3, etc. [
BYP
] = user code 13, [
MEM
] = user code 14, [
TRBL
] = user code 15, and key [2
ND
] = user code 16.
If partitioning is disabled
(Address 206, key [8] "off ")
Address 200: Lighted keys indicate which user codes can activate "stay" arming.
Address 202: Lighted keys indicate which user codes can activate force "away” arming.
Address 204: Lighted keys indicate which user codes can "bypass" zones.
If partitioning is enabled
(Address 206, key [8] "on")
Address 200: Lighted keys indicate which user codes are assigned to System "A".
Address 202: Lighted keys indicate which user codes are assigned to System "B".
Address 204: Lighted keys indicate which user codes can "bypass" zones.
(See also page 26.)
TLM options
(Address 206, key [2
ND
] and key [1])
The system verifies the existence of a telephone line every 4 seconds. After successful tests, the dialer
LED (green light) flashes briefly on control panel. If the test fails, LED illuminates 4 seconds "on", then 4 sec-
onds "off ". TLM trouble will be activated when less than 3 volts are detected in 4 consecutive tests.
Note: When the dialer detects a telephone ring, the TLM flashing stops for 1 minute.
FUNCTION
DESCRIPTION
TYPE
HEXA PROG.
Address
Address
196/197
198/199
Ground start Pulse
Provides
3 sec.
pulse before
5
5/2
[2
ND
]/8
(Timed N.O.)
communication attempt.
Push key [1] and [2]
Provides output when keys [1]
1
5/8
[2
ND
]/6
(Regular N.O.)
and [2] are pressed simultaneously.
System armed
Output removed when system
9
2/B
[2
ND
]/8
(Regular N.C.)
armed.
Strobe output
Provides latching output on
1
2/C
[2
ND
]/2
(Regular N.O.)
alarm, until disarmed.
Fail to communicate
Provides output upon fail to
5
2/6
[2
ND
]/4
(Timed N.O.)
communicate for
2 minutes
.
2nd telephone line relay Provides output after one failed
[2
ND
]
7/A
[2
ND
]/E
(Regular N.O.)
communication attempt.
Kiss off
Provides
3 sec.
output after signal
5
7/D
[2
ND
]/8
(Timed N.O.)
received at monitoring station.
Time output
Provides
3 sec.
output every day
6
2/3
1/4
(Timed N.O.)
at 8PM.
*
Times must be programmed at address 254.
**
Not permitted on UL listed systems
*
*
*
*
**