Programmable Outputs
Almost any control panel status situation may be used to activate the Esprit’s programmable outputs.
Once a panel status mode is selected for a PGM to follow, the polarity and duration of the output may
also be programmed. 18 supplementary programmable outputs are available with the SRI18 module,
which connects to the panel’s serial output.
Espload Upload/Download Software
Espload upload/download software revolutionizes control panel supervision by offering powerful panel
programming, modification, real-time monitoring and data management tools. It functions with most
Hayes-compatible modems, requires only 45 seconds to transmit a full upload or download, and is
extremely simple to learn and operate. The upload/download software is not permitted on UL installations.
Advanced Technology Zoning
Advanced Technology Zoning was developed to permit connection of 2 zones and a tamper on a single
pair of wires, as well as providing wire fault recognition. ATZ simplifies the task of meeting the zone
reguirements of any installation and, at the same time, reduces installation costs.
Alarm Relay (optional-738)
Single pole, double throw dry contacts rated at 5 amps that follow the local alarm (bell/siren) output.
SPECIFICATIONS
Inputs and Outputs:
Maximum Zones:
Varies according to control panel/keypad combination.
639/640 LCD keypads: (See "Keypad Connections", page 8.)
728: 10 zones (4 onboard zones + 4 ATZ zones + 2 keypad zones)
738: 14 zones (6 onboard zones + 6 ATZ zones + 2 keypad zones)
616/626/633 LED keypads: (See "Keypad Connections", page 8.)
728: 9 zones (4 onboard zones + 4 ATZ zones + 1 keypad zone) - using 1 keypad.
728: 10 zones (4 onboard zones + 4 ATZ zones + 2 keypad zones) - using 2 keypads.
738: 13 zones (6 onboard zones + 6 ATZ zones + 1 keypad zone) - using 1 keypad.
738: 14 zones (6 onboard zones + 6 ATZ zones + 2 keypad zones) - using 2 keypads.
Zone Configuration: N.C. (no resistors), EOL (1 resistor), “Advanced Technology Zoning” and
wire/tamper recognition using.
2 resistors per zone. (Zone configuration programmed at address 208)
Battery Charger:
360mA with active Battery test.
Aux power:
400 mA, Fuseless electronic shutdown at 1A, Automatic restore
Bell Out:
1A, Fuseless electronic shutdown at 3A, Automatic restore
AC input:
16.5 Vac, 40VA, 50 - 60Hz
PGM outputs:
More than 1000 options to follow
2 operation modes: Timed (1 sec.-2 hrs.) or following predetermined condition.
N.C. or N.O to ground, 50 mA Max.
Can also be remote-controlled by PC using Espload.
Event Buffer:
120 event buffer with time and date.
Operating Modes:
17 User codes (2 Master codes) 4 or 6 digit codes.
Partitioning to System “A”, System “B”, both systems (dual area), or no system assignment (common area).
Regular, “Stay” (at Home) arming, Force “Away” arming
Fast “One key Full Arm”, “One key Stay Arm” and “One key Exit”.
Key Switch Arm/Disarm ("stay" or "regular" mode).
PS1 bedside remote.
3 keypad-activated panic alarms.
Real Time Clock for "list of events", auto arming and test reports.
Auto arm on “time” or “no zone activity delay time”.