17
There are three options for TLM use.
(1) Line test failure can generate a trouble indication.
(2) Line test failure can generate a trouble indication and an
alarm if the system is armed.
(3) Line test failure will cause silent or panic zones to switch
to audible mode.
Arming using PS1 or keyswitch
(Address 206, key [2] and key [3])
The PS1 bedside remote arming module or keyswitch can be used to stay arm, full arm, or disarm the
system. The PS1 keyswitch is enabled at address 206, key [3].
Key [2] "off": PS1 or keyswitch "regular" arms system.
Key [2] "on": PS1 or keyswitch "stay" arms system.*
*Note: If partitioning is enabled (address 206, key [8] "on"), PS1 arms system "A" only. Use of PS1 is not
recommended for partitioned systems.
Call back
(Address 206, key [4])
For extra security, the panel can be programmed to call the PC back when communication is attempted
by the PC. The panel will first answer the call, then Espload and the panel will verify identification codes.
The panel will then hang up and call the PC back and establish communication. Espload automatically
goes into the “wait for call mode” ready to answer when the panel calls back. The identification codes are
verified again before allowing access to the panel.
Related features: “Computer telephone number” 060-067.
Auto arm
On Time:
(Address 206, key [5])
The panel may be programmed to arm at the same time every day. Program both the hour and minute
(addresses 245, 246) for arming. (This will also be the "auto test report" time, if enabled.) A late closing
code may be programmed (address 190).
Related features:
“
Auto arm” 210, [2]
“Auto/Espload Arm” 188
"Auto arming" p.22.
No Movement:
(Address 206, key [6])
If zone activity is not detected for a programmed period (address 253) while disarmed, the panel can auto
arm and/or send a "no movement" report (address 190). Refer also to "No movement" p. 22.
Touch tone options
(Address 206, key [7])
Tone (key [7] = "on") or pulse dialing can be programmed. If "pulse" is chosen for a central station phone
number, "tone" dialing can be programmed for the other number. [
BYP
] ("switch from pulse to tone")
should be entered in the second phone number during programming.
Partitioning
(Address 206, key [8])
Partitioning is activated, (key [8] "on"). The panel's fully programmable zones (plus 2 remote keypad
zones) can be divided into two systems. (See “System Partitioning”, page 25.)
Silent alarm
(Address 206, key [9])
Key [9] "off":
Silent zones/panics generate only a silent alarm. Zones defined as "silent" at address 216 and keypad
panic zones will not cause an audible alarm, however, the keypad "armed" light will flash and the alarm
condition will remain until a valid user code is entered.
Key [9] "on":
Silent zones/panics generate only a report (The red keypad LED does not flash, and there is no need
to "reset" the silent alarm.)
Silent delay zones generate an entry delay beep, and a report at the end of the entry delay.
Zone restore is always reported upon zone closure.
(default)