IM728-738
Ademco contact ID
(selected codes reported)
(key [9])
Select certain report codes to be reported by entering any value other than [2
ND
][2
ND
] at the required
addresses. The preprogrammed Contact ID report code for that event will then be reported. Default value
of all addresses is [2
ND
][2
ND
].
Ademco express
(key [8])
This high speed reporting format communicates events in 2 seconds.
DTMF - no handshake
([
TRBL
] key)
This format can be utilized in reporting situations where a central station receiver is not connected to the
telephone number. It's useful for personal reporting where a "handshake" is not required. (In "double
reporting" mode, first central station number can be connected to a receiver, while second can be used
for personal reporting using "no handshake" format. The panel will make two attempts to call the "no
handshake" number.)
Standard pulse formats
Ademco slow, Silent Knight, Sescoa, and Radionics are programmable with keys [2
ND
] to [7].
Programmable Output (PGM) Types
(Address 195)
SECTION 33
Regular N.O. Solid state switch conducts to negative (
*
50mA) upon an event or events, and returns to its
original state (N.O) once the conditions that triggered it have terminated.
Regular N.C. Solid state switch opens circuits from ground upon an event or events and returns to its
original state (N.C.) once the conditions that triggered it have terminated.
Timed N.O.
Solid state switch conducts to negative (
*
50mA) upon an event or events and remains acti-
vated for the amount of time programmed at address 254.
Timed N.C. Solid state switch opens circuits from ground upon an event(s) and remains activated for
the amount of time programmed at address 254.
"
OR
" logic
Causes the programmable output command to occur when one or more selected events
from a specified group of events takes place (example: key [1]
OR
[2] is pressed on keypad.)
"
AND
" logic
Causes the programmable output command to occur when all selected events from a spec-
ified group of events take place (example: key [1]
AND
key [2] are pressed.)
"
EQUAL
" logic Causes the programmable output command to occur when all events from a specified
group of events take place (example: key [1] and [2] are pressed but [3], [4], [5], [6], [2
ND
]
and [
TRBL
] are not pressed.)
*
UL tested for 30mA only.