LED
COLOR/FLASHING DESCRIPTION
1
DC-IN
Off
No DC power present
Green
DC power present
2
Power Status LED (PWR)
Off
Camera off
1
Green
Camera on
Amber flashing
Camera on; 5 to 10 min of battery time available
Amber
Camera booting
Red flashing
Camera on; < 5 min of battery time available
Red
Camera shutting down
3
Record Status LED (REC)
Off
No media present
Green
Ready to record
Amber
Finalizing
Red flashing (slow) Media mounted with > 5% and ≤ 10% of media
space available
Red flashing (fast) Media mounted with ≤ 5% of media space
available
Red
Recording
N/A Power Status LED (PWR) and Record
Status LED (REC)
Both green
flashing
Firmware update in progress
Both red flashing
Firmware update error
1. To prevent battery drain, the PWR LED does not illuminate when the camera is off and a power source is present.
COPYRIGHT © 2017 PANAVISION INTERNATIONAL, L.P.
FW: V-0.5.35
|
12
PANAVISION MILLENNIUM DXL