Troubleshooting
OMCTT5639E09
47
E r r
-06
Arc StartError
The arc did not start within 30 seconds after the torch switch was turned on.
• Turn the torch switch off, and the error indication disappears automatically.
• Refer to page 14-3, and remove the causes why the arc did not start accord
-
ingly.
E r r
-07
TorchSW Error
This product was switched on with the torch switch turned on.
• Turn off the power of this product and the torch switch, and then turn on only
the power switch again.
• As for the torch switch, turn it on at least 3 seconds after turning the power
switch on for safety reasons.
E r r
-08
Curr.DetectError
It may be failure of this product.
Please contact sales distributor or Panasonic representative.
E r r
-11
WaterCircuitErr
A “WaterCircuitErr” signal was input from external equipment, such as
cooling-water equipment, etc. connected to the jig terminal.
• When the input of the
“WaterCircuitErr”
signal is stopped, the error indication
disappears automatically.
• Check for the clogging of cooling-water equipment, the concentration of coolant
solution, the bending of supply and return hoses for the torch cable, etc. to
secure the flow rate of cooling water.
E r r
-12
GAS Protection
It may be failure of this product.
Please contact sales distributor or Panasonic representative.
E r r
-13
Sec. OverVoltage
During the MIX TIG and AC TIG welding, the output-side cables are used
winding them in small coils.
• Use the output-side cables preferably without winding them in coils
(When using them in a state of coils unavoidably, wind them in 300É” or larger
coils.) (See section “Connection: Output cables”)
• To reset, turn the power off.
E r r
C30
|
C39
A status is indicated
according to each
number indication.
Indicates the contents of a communication error between external devices (per
-
sonal computer, etc.) and this product.
• When this error occurs, turn off the power of the external device and this prod
-
uct. (Power reset)
-
-
CT Offset Error
It may be failure of this product.
Please contact sales distributor or Panasonic representative.
-
-
System Mem.Fail!
Notice
About “Err-06:Arc StartError
When the arc does not start for more than 2 seconds after turning the torch switch on, the high frequency wave is gener
-
ated intermittently for safety reasons on the basis that some failure (See page 14-3) has occurred, and after additional 30
seconds or more, the “Err-06 Arc start error” is indicated and the operation is stopped.
Notice
About “Err-05:Pri. LowVoltageÅh at power off
when turning the power off, it is not an error. (It is just indication of detection of the reduced primary voltage due to the
power cutoff.)
E r r
Code
Message
Remedy
Summary of Contents for YC-300BP2YAF
Page 10: ...Rated Specifications OMCTT5639E09 10 2 2 1 Dimensions ...
Page 16: ...Installation OMCTT5639E09 16 Example of extension cable connection ...
Page 49: ...Parts list OMCTT5639E09 49 9 Parts list ...
Page 52: ...OMCTT5639E09 52 ...
Page 53: ...Circuit diagram OMCTT5639E09 53 10 Circuit diagram NF9 NF8 ...
Page 54: ...Circuit diagram OMCTT5639E09 54 10 1 Enlarged left half NF8 MCB ...
Page 55: ...Circuit diagram OMCTT5639E09 55 10 2 Enlarged right half NF9 ...
Page 62: ...OMCTT5639E09 62 ...
Page 63: ...OMCTT5639E09 63 ...